Re: bug in smsc_smpp.c login failure

Nisan Bloch <[email protected]>
Newsgroups gmane.comp.mobile.kannel.devel
Message-ID <[email protected]>
Hi
At 03:46 PM 2/27/03 +1300, Alan McNatty wrote:
>Hello,
>
>found that if I type in the smpp password incorrectly kannel loops
>forever trying to reconnect. ie:


-1 from me
In the current form this path will not allow any retries for any sort of 
bind error. eg what happens if there is a temporary connectivity issue, or 
the SMPP server is down for a short while/

Nisan


>  [6] DEBUG: SMPP PDU 0x80f3a18 dump:
>  [6] DEBUG:   type_name: bind_receiver_resp
>  [6] DEBUG:   command_id: 2147483649 = 0x80000001
>  [6] DEBUG:   command_status: 14 = 0x0000000e
>  [6] DEBUG:   sequence_number: 732 = 0x000002dc
>  [6] DEBUG:   system_id: NULL
>  [6] DEBUG: SMPP PDU dump ends.
>  [6] ERROR: SMPP[xxx]: SMSC rejected login to receive, code 0x0000000e.
>  [6] ERROR: SMPP[xxx]: I/O error or other error. Re-connecting.
>
>And so on ..
>
>The smsc_smpp.c handle_pdu notices the error (and indeed reports on it)
>but it's not noticed at the io_thread level so keeps trying.
>
>I worked around it by setting smpp->quitting = 1 after the error message
>in handle_pdu (see patch) which has the effect of shutting down the
>failing threads (so they don't keep trying). Crude - provided as example
>only - will look at improving this.
>
>Also, in the instance you only have 1 smpp connection which when fails
>in this way, the bearerbox sits without actually shutting down (ie:
>doesn't realise there are no active threads and clean up, etc). Should
>the bearerbox shutdown in this instance?
>
>Cheers,
>Alan
>
>
>--
>Alan McNatty <[email protected]>
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.