Re: Siemens S55 WAP problems fixed?! PATCH
Aarno Syvänen <[email protected]>
| Newsgroups | gmane.comp.mobile.kannel.devel |
|---|---|
| Message-ID | <[email protected]> |
All WSP parsers should accept any text string as content type, and pass it to the server unmodified. See content-type-value productions: Content-Type-value = Constrained-media | Content-general-form Content-general-form = Value-length Media-Type Media-Type = (Well-known-media | Extension-Media) *(Parameter) and Extension-media: Extension-Media = *TEXT End-of-string On Saturday, April 19, 2003, at 07:03 PM, Stipe Tolj wrote: > -1 for this patch. This is the "too easy" solution and breaks our new > MMS encoder/decoder routines that are based on WSP parsing code. > > Beware that Nokia and Ericsson *do* use the tokenized form in their > WSP headers, so we have to take care to be able to read them. > > Stipe > > [email protected] > ------------------------------------------------------------------- > Wapme Systems AG > > Vogelsanger Weg 80 > 40470 Düsseldorf > > Tel: +49-211-74845-0 > Fax: +49-211-74845-299 > > E-Mail: [email protected] > Internet: http://www.wapme-systems.de > ------------------------------------------------------------------- > wapme.net - wherever you are >