Re[2]: Siemens S55 WAP problems fixed?! PATCH

Jury Cherepanov <[email protected]>
Newsgroups gmane.comp.mobile.kannel.devel
Organization HighTech
Message-ID <[email protected]>
Hello Aarno,

Tuesday, April 22, 2003, 12:25:19 PM, you wrote:

AS> All WSP parsers should accept any text string as content type, and pass 
AS> it
AS> to the server unmodified. See content-type-value productions:

AS> Content-Type-value = Constrained-media | Content-general-form
AS> Content-general-form = Value-length Media-Type
AS> Media-Type = (Well-known-media | Extension-Media) *(Parameter)

AS> and Extension-media:

AS>   Extension-Media = *TEXT End-of-string

AS> On Saturday, April 19, 2003, at 07:03 PM, Stipe Tolj wrote:

>> -1 for this patch. This is the "too easy" solution and breaks our new
>> MMS encoder/decoder routines that are based on WSP parsing code.
>>
>> Beware that Nokia and Ericsson *do* use the tokenized form in their
>> WSP headers, so we have to take care to be able to read them.
>>
>> Stipe
>>
>> [email protected]
>> -------------------------------------------------------------------
>> Wapme Systems AG
>>
>> Vogelsanger Weg 80
>> 40470 Düsseldorf
>>
>> Tel: +49-211-74845-0
>> Fax: +49-211-74845-299
>>
>> E-Mail: [email protected]
>> Internet: http://www.wapme-systems.de
>> -------------------------------------------------------------------
>> wapme.net - wherever you are
>>

Yes. I'm say that according WSP specification.



---------------------------------------------------------
Jury Cherepanov
System Developer (Technical Director) , HIGH TECHNOLOGIES
Turaidas 2a, Riga, Latvia
Phone +371-9633398
mailto:[email protected]
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.