Re: Bearerbox bug?
Nisan Bloch <[email protected]>
| Newsgroups | gmane.comp.mobile.kannel.devel |
|---|---|
| Message-ID | <[email protected]> |
At 11:00 AM 4/23/03 +0200, Stipe Tolj wrote: >AFAIR, when I wrote the start|stop-smsc facilities it was a sequential >search in the list of current smscs. So it will break after it found >one smsc with the id you provided. yup, which means if one has two smscs with the same smsc-id you have problems. >This may be addopted to run the whole list and stop|start any smsc-ids >that match the id. Not really.. one cannot then specify a specific instance to be restarted as they have the same smsc-id >Votes for changing this? I'm +0 on this. Besides that same smsc-ids >are allowed, so semantically they should stop all, right? Well you may not want to or need to stop all connections with the same smsc-id We have added a extra param smsc-ctrl-id - which defaults to smsc-id and is used in the stop/start code. nisan >Stipe > >[email protected] >------------------------------------------------------------------- >Wapme Systems AG > >Vogelsanger Weg 80 >40470 Düsseldorf > >Tel: +49-211-74845-0 >Fax: +49-211-74845-299 > >E-Mail: [email protected] >Internet: http://www.wapme-systems.de >------------------------------------------------------------------- >wapme.net - wherever you are