Re: siemens seo problems

Aarno Syvänen <[email protected]>
Newsgroups gmane.comp.mobile.kannel.devel
Message-ID <[email protected]>
Do you have ota spec for siemens ? If you do, is it public ?

Aarno

On Monday, July 14, 2003, at 10:40 AM, Dziugas Baltrunas wrote:

> Hi list,
>
> I remember that there was an intereset in mailing list about Siemens  
> SEO,
> especially Illimar Reinbusch, who reported that is's working for him
> (http://www.mail-archive.com/[email protected]/msg00221.html)
>
> here is my code (72x14 bitmap, Windows BMP format):
>
> http://smsbox.m-1.lt:13013/cgi-bin/ 
> sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=// 
> SEO%01%6C%00%00%00%00%00%01%00%03%00%E6%00%00%00%03bmp%07683.bmp%42%4d% 
> e6%00%00%00%00%00%00%00%3e%00%00%00%28%00%00%00%48%00%00%00%0e%00%00%00 
> %01%00%01%00%00%00%00%00%a8%00%00%00%6d%0b%00%00%6d%0b%00%00%02%00%00%0 
> 0%02%00%00%00%00%00%00%00%ff%ff%ff%00%fe%3f%d8%f7%f7%ef%db%fc%7f%75%65% 
> 73%fd%df%b7%f7%f7%ef%ed%fb%bf%6c%73%27%fb%bf%36%e9%c3%97%6d%fd%df%44%5f 
> %4f%fb%7f%6f%6e%00%70%c6%fe%df%73
> http://smsbox.m-1.lt:13013/cgi-bin/ 
> sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=// 
> SEO%01%6C%00%00%00%00%00%02%00%03%00%E6%00%00%00%03bmp%07683.bmp%75%62% 
> cb%bc%67%9f%81%fb%96%3d%d3%75%65%73%b5%c1%63%bf%81%fd%f6%83%ad%6c%73%20 
> %73%eb%6d%7f%7e%fe%e6%d7%ce%24%73%65%73%eb%67%7f%bd%fe%e6%d7%ce%74%3b%0 
> a%b5%c1%66%f0%18%0f%66%83%ad%76%2c%24%cb%bc%66%e6%3c%67%46%3d%d3%5f%3b% 
> 0a%fb%7f%66%e6%7e%67%76%fe%df%20%24%76%fb%bf%b6%f0%eb%0f%6d%fd%df%76%29 
> %20%fd%df%b6%c3%d5%c3%6d%fb%bf%20
> http://smsbox.m-1.lt:13013/cgi-bin/ 
> sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=// 
> SEO%01%6C%00%00%00%00%00%03%00%03%00%E6%00%00%00%03bmp%07683.bmp%26%26% 
> fe%3f%da%ff%b6%ff%5b%fc%7f%29%3b%0a%00%00%00%00%00%00%00%00%00%00%00%00 
> %00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%0 
> 0%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00% 
> 00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00 
> %00%00%00%00%00%00%00%00%00%00%00
>
> everything is done by example in contrib/web/sendsms.php except the  
> last
> message, because, acording to "OTA Specification release", last SM has  
> to
> be filled with zeros, i.e. 0x00, so "Data size" for every SM segment  
> must
> be the same (here it's 140 - 22 - 3 - length(683.bmp) = 108 octets).
>
> when i try to send these messages to Siemens ME45, phone keeps silent  
> and
> here is no asking for indication.
>
> what might be wrong here? Illimar, are you alive?! ;)
>
> regards,
> Dziugas Baltrunas
>
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.