Hi,

I have solved all my problems - bitmaps and midi files are now working
fine. Thanks Illimar for the help.

Next week I will try to write some tutorial based on Siemens and maybe
EMS smart messaging.

I put Siemens OTA spec in
http://soften.ktu.lt/~menulis/OTA_Specification_Release1.0.2.pdf

but I'm sure, that it could be found somewhere in siemens.com (I found it
myself some time ago). By the way, in my opinion, there is a mistake in
given example about the total size of bitmap (103x8 != 750).

If you have any related questions - please ask ;)

Have a nice weekend, guys.

regards,
Dziugas Baltrunas

On Fri, 18 Jul 2003, [ISO-8859-1] Aarno Syvänen wrote:

> Do you have ota spec for siemens ? If you do, is it public ?
>
> Aarno
>
> On Monday, July 14, 2003, at 10:40 AM, Dziugas Baltrunas wrote:
>
> > Hi list,
> >
> > I remember that there was an intereset in mailing list about Siemens
> > SEO,
> > especially Illimar Reinbusch, who reported that is's working for him
> > (http://www.mail-archive.com/[email protected]/msg00221.html)
> >
> > here is my code (72x14 bitmap, Windows BMP format):
> >
> > http://smsbox.m-1.lt:13013/cgi-bin/
> > sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=//
> > SEO%01%6C%00%00%00%00%00%01%00%03%00%E6%00%00%00%03bmp%07683.bmp%42%4d%
> > e6%00%00%00%00%00%00%00%3e%00%00%00%28%00%00%00%48%00%00%00%0e%00%00%00
> > %01%00%01%00%00%00%00%00%a8%00%00%00%6d%0b%00%00%6d%0b%00%00%02%00%00%0
> > 0%02%00%00%00%00%00%00%00%ff%ff%ff%00%fe%3f%d8%f7%f7%ef%db%fc%7f%75%65%
> > 73%fd%df%b7%f7%f7%ef%ed%fb%bf%6c%73%27%fb%bf%36%e9%c3%97%6d%fd%df%44%5f
> > %4f%fb%7f%6f%6e%00%70%c6%fe%df%73
> > http://smsbox.m-1.lt:13013/cgi-bin/
> > sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=//
> > SEO%01%6C%00%00%00%00%00%02%00%03%00%E6%00%00%00%03bmp%07683.bmp%75%62%
> > cb%bc%67%9f%81%fb%96%3d%d3%75%65%73%b5%c1%63%bf%81%fd%f6%83%ad%6c%73%20
> > %73%eb%6d%7f%7e%fe%e6%d7%ce%24%73%65%73%eb%67%7f%bd%fe%e6%d7%ce%74%3b%0
> > a%b5%c1%66%f0%18%0f%66%83%ad%76%2c%24%cb%bc%66%e6%3c%67%46%3d%d3%5f%3b%
> > 0a%fb%7f%66%e6%7e%67%76%fe%df%20%24%76%fb%bf%b6%f0%eb%0f%6d%fd%df%76%29
> > %20%fd%df%b6%c3%d5%c3%6d%fb%bf%20
> > http://smsbox.m-1.lt:13013/cgi-bin/
> > sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=//
> > SEO%01%6C%00%00%00%00%00%03%00%03%00%E6%00%00%00%03bmp%07683.bmp%26%26%
> > fe%3f%da%ff%b6%ff%5b%fc%7f%29%3b%0a%00%00%00%00%00%00%00%00%00%00%00%00
> > %00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%0
> > 0%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%
> > 00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00
> > %00%00%00%00%00%00%00%00%00%00%00
> >
> > everything is done by example in contrib/web/sendsms.php except the
> > last
> > message, because, acording to "OTA Specification release", last SM has
> > to
> > be filled with zeros, i.e. 0x00, so "Data size" for every SM segment
> > must
> > be the same (here it's 140 - 22 - 3 - length(683.bmp) = 108 octets).
> >
> > when i try to send these messages to Siemens ME45, phone keeps silent
> > and
> > here is no asking for indication.
> >
> > what might be wrong here? Illimar, are you alive?! ;)
> >
> > regards,
> > Dziugas Baltrunas
> >
>
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.