Issues connecting to a new type of SMSC

"Jarrod Hermer" <[email protected]>
Newsgroups gmane.comp.mobile.kannel.devel
Message-ID <008001c37c6a$a20bdd50$2701a8c0@lonewolf>
Hi Guys,

Please bear with me as I am most certainly not technically capable of
solving this problem myself, or even understanding it for that matter.

One of the networks that we connect to has changed to a different type
of SMSC. The full name of the product is: SchlumbergerSema MGA Gateway
v2.2
- With VMS GSM SMSC G9.0 & Higher

I am consistently experiencing error messages in my logs. I have
discussed it with the network in question. I have included the errors
and their response; can anybody assist in solving this problem?


2003-08-18 18:15:51 [35] ERROR: SMPP[VODACOM_MGA2_1902114]: SMSC
rejected login to transmit, code 0x0000000d. 2003-08-18 18:15:51 [35]
ERROR: SMPP[VODACOM_MGA2_1902114]: I/O error or other error.
Re-connecting.

ANSWER From experience most SP's do not supply the "interface_version"
in "Bind_transceiver" PDU. Please look into the Protocol Spec down
loadable on the www.smsforum.org and the this field as its mandatory.

code 0x0000000d from the Protocol spec is "Bind_failed"


2003-08-18 18:15:51 [35] WARNING: SMPP: PDU NUL terminated string has no
NUL.

ANSWER SMPP PDU and type definations: 
The following SMPP PDU data type defininations are used to define the
SMPP parameters:

Integer        An unsigned value with the defined number of octets.
C-Octet String: A series of ASCII characters terminated with NULL
character. C-Octet String (HEX): A series of ASCII characters each
character representing a hexadecimal digit (0-F) and terminated with the
NULL character.

Please check on how you terminating your PDU's.

-----------------------------------END----------------------------------
-


Thanks,
Jarrod
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.