Re:

Andreas Fink <[email protected]>
Newsgroups gmane.comp.mobile.kannel.devel
Message-ID <[email protected]>
On 24.10.2008, at 09:11, Trowa Barton wrote:

> Hi,
>
> I have 2 questions regarding EMI/UCP.
> I have set concatenation = true and flow-control = 1 in my kannel  
> config.
> I am using 1.4.1
>
> /*
> group = smsc
> smsc = emi
> smsc-id = incomming
> allowed-smsc-id = outgoing
> host = xxx.xxx.xxx.xxx
> port = xxx
> smsc-username = xxxx
> smsc-password = xxxx
> keepalive = 120
> sender-prefix = ""
> flow-control = 1
>
> group = sendsms-user
> username = xxxx
> password = xxxx
> concatenation = true
> max-messages = 3
> default-smsc = incomming
> */
>
>
> 1. When I try to send 430 characters (concatenated) the last part is
> being sent first and the first part is being sent last. When starting
> kannel it sends in the correct order. 1-2-3.. But if I send another
> message it send 3-2-1. The message is the same. So I always need to
> restart kannel to send in the correct order. This doesnt happen in
> cimd2. The first part is being sent first. Always.


This is absolutely irrelevant. The phone will display the whole  
message once all parts have been received. If they arrive 1-2-3 or  
3-2-1 or 3-1-2 doesn't really matter.
The order can also be messed up in transmission to the phone. like you  
are about to drive in the tunnel, you get 1 and when you exit you get  
3 and 10 minutes later after retry you get 2.



> 2. Assuming my first problem is fixed. My current telco is sending
> (05) error which means 'call baring active' so when the first part of
> the message and I got a response is 05 i should stop sending the 2nd
> and 3rd part of the concatenated message.

Call Barring active means the subscriber is not allowed to receive ANY  
messages (unpaid bill for example...)
This has nothing to do with multipart.





Andreas Fink

Fink Consulting GmbH
Global Networks Schweiz AG
BebbiCell AG
IceCell ehf

---------------------------------------------------------------
Tel: +41-61-6666330 Fax: +41-61-6666331  Mobile: +41-79-2457333
Address: Clarastrasse 3, 4058 Basel, Switzerland
E-Mail:  [email protected]