Re: [PATCH] smsc_at2.c error string
Alexander Malysh <[email protected]>
| Newsgroups | gmane.comp.mobile.kannel.devel |
|---|---|
| Message-ID | <[email protected]> |
commited to cvs. Thanks, Alex Am 17.06.2009 um 14:26 schrieb Vincent CHAVANIS: > This one should fit. > > Vincent. > > Alexander Malysh a écrit : >> sorry, but still the same: >> + case 0: >> + /* >> + * Default the code to 0 then when you extract the value >> from the >> + * modem response message and no code is found, 0 will result. >> + */ >> + return "Modem returned ERROR but no error code - possibly >> unsupported or invalid command?"; >> indents are 4 spaces instead of 2. >> Thanks, >> Alex >> Am 17.06.2009 um 13:24 schrieb Vincent CHAVANIS: >>> yep, you're right. >>> >>> new file attached. >>> without blank comments, and text cleaned. >>> >>> Vincent. >>> >>> Alexander Malysh a écrit : >>>> Hi Vincent, >>>> some comments: >>>> + error(0, "AT2[%s]: [%d/%ld] Initialization of device >>>> failed.", octstr_get_cstr(privdata->name), >>>> + error_count, privdata->max_error_count); >>>> this is not very informative for kannel user. Please write out >>>> something like Init failed errors X from max errors X. >>>> please kill comments like this: >>>> + /* >>>> + */ >>>> please fix indentation, we use 4 spaces... >>>> Thanks, >>>> Alex >>>> Am 17.06.2009 um 12:56 schrieb Vincent CHAVANIS: >>>>> >>>>> From an old thread (http://www.mail-archive.com/[email protected]/msg07693.html >>>>> ) >>>>> Alex moved the at2_error_string into smsc_at.c >>>>> >>>>> 2004-09-18 Alexander Malysh <amalysh at kannel.org> >>>>> * gw/smsc/smsc_at.c: added new function 'at2_error_string' and >>>>> teached >>>>> smsc_at to use it. >>>>> >>>>> But some error codes are missing. >>>>> 1472:2009-06-16 16:00:59.0442 [2255] [8] ERROR: AT2[WAVECOM]: >>>>> Generic error: +CME ERROR: 515 >>>>> 2710:2009-06-16 23:35:40.0142 [2255] [8] ERROR: AT2[WAVECOM]: >>>>> CMS ERROR: +CMS ERROR: 513 >>>>> 2711:2009-06-16 23:35:40.0142 [2255] [8] ERROR: AT2[WAVECOM]: >>>>> CMS ERROR: Error number unknown. Ask google and add it. (513) >>>>> >>>>> Each code is more or less detailled on comments >>>>> I think this should be left as it as there are no documentation >>>>> on it. >>>>> >>>>> This patch also prints the counter before the reset-string. >>>>> >>>>> Vincent. >>>>> >>> <smsc_at2_error_string_patch_v2.txt> > > -- > Telemaque - 06560 SOPHIA-ANTIPOLIS - (FR) > Service Technique/Reseau - NOC > Direction du Developpement xMS+ > http://www.telemaque.fr/ > [email protected] > Tel : +33 4 92 90 99 84 (fax 9142) > <smsc_at2_error_string_patch_v3.txt>