=?windows-1256?Q?Handling_t?= =?windows-1256?Q?hrottling_?= =?windows-1256?Q?and_messag?= =?windows-1256?Q?e_queue_fu?= =?windows-1256?Q?ll_errors=FE?= =?windows-1256?Q?=FE?=

tolis man <[email protected]>
Newsgroups gmane.comp.mobile.kannel.devel
Message-ID <[email protected]>
Hello I have a question concerning some specific behaviour of kannel on 2 specific errors
This behaviour is a requirement for one smsc connection, I have also posted this on commercial mailing list of kannel, unfortunately I didn't get any response.

What I need to setup is:

for the errors:

1. 0x58 Throttling Error
2. 0x14 Message Queue Full

--

1. The requirement says that when I receive a throttling error message (0x58), the needed behaviour is:

Stop sending any Submit_sm for 60 seconds. Any more outgoing Submit_sm's must be placed to the queue. The message, which get an error must be placed 1st in the queue. 
After 60 seconds timeout, continue sending normally, according queue.

2. If I receive a Message Queue Full error (0x14), the needed behaviour is:

Resend message. Try to resend it only 3-5 times. Every time you get an error, place message at very end of queue.

--

The smsc connection I have setup is:

group = smsc
smsc = smpp
source-addr-ton = 0
source-addr-npi = 1
dest-addr-ton = 1
dest-addr-npi = 1
enquire-link-interval = 60
reconnect-delay = 90
throughput = 1
max-pending-submits = 1
wait-ack = 60
validityperiod = 4340

*It must be in synchronous mode too...

I need to fix the behaviour of this connection for these two errors.
Is there anyone who could help me on this? If so please email me.