Re: vr0: tx shutdown timeout
Chris Buechler <[email protected]>
| Newsgroups | gmane.comp.security.firewalls.m0n0wall |
|---|---|
| Message-ID | <[email protected]> |
On Thu, Aug 27, 2009 at 8:10 PM, Richard Parvass<[email protected]> wrote: > During heavy traffic, I get the following errors logged a few times over a > short period, then the network connection, despite being "up" is not > responding and no traffic passes. This did not happen until a nightly > offsite backup was put in place over the link. There is no way to throttle > the traffic generated. > > kernel: vr0: tx shutdown timeout > kernel: vr0: restarting > > Running ifconfig vr0 down; ifconfig vr0 up from exec.php restores network > connectivity. > > It appears to be a bug within FreeBSD which was possibly fixed with a > patch way back in v4.7, but the patch seems to have regressed in 1.3b15's > FreeBSD which this system is running. > There are a number of edge case vr(4) issues in FreeBSD 6.x that weren't fixed until 7.x. This is among them I suspect. m0n0wall 1.3 will be on 6.4, the following release will be on 7.x and should fix that. In the mean time, it sounds like this is a serious problem in your circumstance, so your best option for a quick resolution is probably using pfSense. Putting a switch between that port on m0n0wall and the device it plugs into might be a good work around since it seems to be specific to half duplex connections.