Re: vr0: tx shutdown timeout

Chris Buechler <[email protected]>
Newsgroups gmane.comp.security.firewalls.m0n0wall
Message-ID <[email protected]>
On Thu, Aug 27, 2009 at 8:10 PM, Richard
Parvass<[email protected]> wrote:
> During heavy traffic, I get the following errors logged a few times over a
> short period, then the network connection, despite being "up" is not
> responding and no traffic passes. This did not happen until a nightly
> offsite backup was put in place over the link. There is no way to throttle
> the traffic generated.
>
> kernel: vr0: tx shutdown timeout
> kernel: vr0: restarting
>
> Running ifconfig vr0 down; ifconfig vr0 up from exec.php restores network
> connectivity.
>
> It appears to be a bug within FreeBSD which was possibly fixed with a
> patch way back in v4.7, but the patch seems to have regressed in 1.3b15's
> FreeBSD which this system is running.
>

There are a number of edge case vr(4) issues in FreeBSD 6.x that
weren't fixed until 7.x. This is among them I suspect. m0n0wall 1.3
will be on 6.4, the following release will be on 7.x and should fix
that. In the mean time, it sounds like this is a serious problem in
your circumstance, so your best option for a quick resolution is
probably using pfSense. Putting a switch between that port on m0n0wall
and the device it plugs into might be a good work around since it
seems to be specific to half duplex connections.
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.