Just for the archives, I also posted this to midrange-l (after the topic
wavered over to system values). But Tom, I agree. QSTRPRTWTR doesn't get
reset until the next IPL.
Luckily I have an iseries that I can IPL at will.
I did extensive testing on this. As we know, QSTRPRTWTR is not a system
value that we can change, it is only a display one. Much like QIPLSTS,
QABNORMSW, etc. If you want an action like a mythical CHGSYSVAL
QSTRPRTWTR would be, then you can do this one of two ways: One, IPL in
manual mode and override it. Two, prior to the IPL do a CHGIPLA
STRPRTWTR(... If you set it to *NO then after the next IPL QSTRUP will
not start the writers and system value QSTRPRTWTR will be set to 0, do not
start. Somewhere during, or after, the IPL it does a CHGIPLA again and
sets the value for STRPRTWTR back to it's default of *YES, so the NEXT ipl
will automatically start printer writers and set the system value
QSTRPRTWTR back to it's default.
I can work with this. My program worked fine.
Rob Berendt
--
Group Dekko Services, LLC
Dept 01.073
PO Box 2000
Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
[email protected] (Tom Liotta)
Sent by: security400-bounces-Zwy7GipZuJhWk0Htik3J/[email protected]
01/19/2005 08:14 PM
Please respond to
Security Administration on the AS400 / iSeries <security400-Zwy7GipZuJhWk0Htik3J/[email protected]>
To
security400-Zwy7GipZuJhWk0Htik3J/[email protected] (Security Administration on the AS400 / iSeries)
cc
Subject
RE: [Security400] Anyone see a security issuewith
CHGJOBDJOBD(QSYS/QSTRUPJD) USER(GODLIKE)?
[email protected] wrote:
>But if I previously called QSYS/QSTRUP I want to make sure that
QSTRPRTWTR
>is not reset by that. So, at what point does that get reset? This is
not
>a system value you can do CHGSYSVAL on. Just want to make sure that if I
>am doing some special IPL that I don't start the printer writers
>unnecessarily.
Rob:
See extended help for system value QSTRPRTWTR. I've never checked, but I
don't think it gets "reset" during IPL. Once it's on, it stays on until
the next IPL. A simple CLP showed it on here.
Tom Liotta
--
Tom Liotta
The PowerTech Group, Inc.
19426 68th Avenue South
Kent, WA 98032
Phone 253-872-7788 x313
Fax 253-872-7904
http://www.powertech.com
__________________________________________________________________
Switch to Netscape Internet Service.
As low as $9.95 a month -- Sign up today at
http://isp.netscape.com/register
Netscape. Just the Net You Need.
New! Netscape Toolbar for Internet Explorer
Search from anywhere on the Web and block those annoying pop-ups.
Download now at http://channels.netscape.com/ns/search/install.jsp
_______________________________________________
This is the Security Administration on the AS400 / iSeries (Security400)
mailing list
To post a message email: Security400-Zwy7GipZuJhWk0Htik3J/[email protected]
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/security400
or email: Security400-request-Zwy7GipZuJhWk0Htik3J/[email protected]
Before posting, please take a moment to review the archives
at http://archive.midrange.com/security400.
_______________________________________________
This is the Security Administration on the AS400 / iSeries (Security400) mailing list
To post a message email: Security400-Zwy7GipZuJhWk0Htik3J/[email protected]
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/security400
or email: Security400-request-Zwy7GipZuJhWk0Htik3J/[email protected]
Before posting, please take a moment to review the archives
at http://archive.midrange.com/security400.
lmpx.com only provides a reader for public news (NNTP) servers. It is not
affiliated with the servers or forums shown here and is not responsible for
the content of articles, which is written by their respective authors.