Re: bind2 pmda qa problem
"Ken McDonell" <[email protected]> Wed, 15 Feb 2017 21:49:39 +1100
| Newsgroups | gmane.comp.sysutils.pcp |
|---|---|
| Message-ID | <[email protected]> |
On 15/02/17 21:28, Lukáš Oliva wrote: > That is interesting. The hashing root of cause is a good guess but as > far as I remember this is well handled in the code (I will check it when > I get to the computer). More likely it seems to me that the > autodetection of metrics and instances I am reworking now fired again > and caused the instances to get renumbered. Were there any restarts od > Pmda or pmcd or a period of unavailability of the Bind server? This test re-installs the PMDA once for each of two test data xml files, so there are restarts of the PMDA, but no bind server being accessed as far as I can see. -=-=-=-=-=-=-=-=-=-=-=- Groups.io Links: You receive all messages sent to this group. View/Reply Online (#15176): https://groups.io/g/pcp/message/15176 View All Messages In Topic (6): https://groups.io/g/pcp/topic/4365733 Mute This Topic: https://groups.io/mt/4365733?uid=174580 New Topic: https://groups.io/g/pcp/post -=-=- pcp mailing list [email protected] https://groups.io/g/pcp/messages -=-=- Change Your Subscription: https://groups.io/g/pcp/editsub?uid=174580 Group Home: https://groups.io/g/pcp Contact Group Owner: [email protected] Terms of Service: https://groups.io/static/tos Unsubscribe: https://groups.io/g/pcp/leave/354243/563757577/xyzzy -=-=-=-=-=-=-=-=-=-=-=-