Re: ITM Agents Logging Event Dectection in Milliseconds
Jay Slay <[email protected]>
| Newsgroups | gmane.comp.sysutils.tivoli.general,gmane.comp.sysutils.tivoli.tme10 |
|---|---|
| Message-ID | <[email protected]> |
This requirement sounds like one that would make me ask "why" about 5 times in a row... -jks On Feb 15, 2013, at 11:32, John Alvord <jalvord-r/[email protected]> wrote: > For sampled situations, the minimum re-evaluation interval is 30 seconds*. > > For pure situations like Unix Log Agent, the logs are rechecked every second. > > I am not sure how to answer their need... at a millisecond level. most measured items are running at 0% or 100%... > > I suspect they have not though through all the issues. > > * I know how to tweak a situation to change that lower - not with Situation Editor... but 1 second is the minimum. At that level the Agent might be consuming 50-80% of the system CPU - which does not sound practical. > > Regards, > > > > John Alvord - Ph: 1-720-396-2788 Cell: none > Customer Support - Tivoli Software - jalvord-r/[email protected] > Advisory Engineer - Tivoli Monitoring - ITM infrastructure > Follow us on Twitter! @Tivolisupport and Facebook > Personalize your support needs with the IBM Support Portal > Use Service Request to get assistance! > For emails regarding a PMR, copy [email protected] > For secure browser uploads: https://www.ecurep.ibm.com/app/upload > For Customer Support guidance: IBM Software Support Handbook > > > > > > > From: Gregory Mendes <[email protected]> > To: <[email protected]>, > Date: 02/15/2013 07:58 AM > Subject: [TME10] ITM Agents Logging Event Dectection in Milliseconds > Sent by: [email protected] > > > > Hello All, > > I have a customer that has a requirement for millisecond logging of ITM agent events when they occur. I know that the Linux OS Agent and the Disk I/O situation can monitor in milliseconds. However, the real requirement is when an ITM agent detects a situation of any type, can it log that detection in a log file in milliseconds. I only see HH:MM:SS from local and global timestamps. > > Regards, > > Gregory R. Mendes > 770-317-8593 > _______________________________________________ > TME10 mailing list > [email protected] > Unsubscribe:[email protected] > > _______________________________________________ > TME10 mailing list > [email protected] > Unsubscribe:[email protected] _______________________________________________ TME10 mailing list [email protected] Unsubscribe:[email protected]