RE: ITM Agents Logging Event Dectection in Milliseconds
Gregory Mendes <[email protected]>
| Newsgroups | gmane.comp.sysutils.tivoli.general |
|---|---|
| Message-ID | <BAY148-W435EADC5019E1F4A04B150F70E0__34329.3118327439$1360954698$gmane$org@phx.gbl> |
Hey John, Thanks again for that clarification. Thats the answer I was looking for and I was confusing it with candle time or expirytime for CYYMMDDHHMMSSmmm. I'll see you at Pulse. Regards, Gregory R. Mendes Tivoli Architect/Tools Specialist Mendes, Inc. Tivoli Monitoring 6.2.3 Certified 770-317-8593 To: [email protected] Subject: RE: [TME10] ITM Agents Logging Event Dectection in Milliseconds From: jalvord-r/[email protected] Date: Fri, 15 Feb 2013 10:33:36 -0800 Oh.... answer is still no. The last three digits are used to keep an arrival sequence number... so if 20 results arrive in a single second, you would see 001 002 003 ... 019 999 The 999 is an end of sequence marker. Occasionally more then 999 come in a single second and you see the Sequence Number Overflow 999 message. Customer can always right an Agent Builder agent, and record the current time down to the nano-second. Regards, John Alvord - Ph: 1-720-396-2788 Cell: none Customer Support - Tivoli Software - jalvord-r/[email protected] Advisory Engineer - Tivoli Monitoring - ITM infrastructure Follow us on Twitter! @Tivolisupport and Facebook Personalize your support needs with the IBM Support Portal Use Service Request to get assistance! For emails regarding a PMR, copy [email protected] For secure browser uploads: https://www.ecurep.ibm.com/app/upload For Customer Support guidance: IBM Software Support Handbook From: Gregory Mendes <[email protected]> To: <[email protected]>, Date: 02/15/2013 10:12 AM Subject: RE: [TME10] ITM Agents Logging Event Dectection in Milliseconds Sent by: [email protected] Hey John, Thanks for that information but I wasn't asking about sampling intervals. What I need to know but can't seem to find in any *.env, *.ini, *.properties, etc, can the Local and Global Timestamps caputure or be configured in milliseconds when an event is sampled. So, when the ITM agent detects the event the requirement is to store that in the log file in HH:MM:SS:millisecond and not HH:MM:SS. Regards, Gregory R. Mendes 770-317-8593 To: [email protected] Subject: Re: [TME10] ITM Agents Logging Event Dectection in Milliseconds From: jalvord-r/[email protected] Date: Fri, 15 Feb 2013 08:32:25 -0800 For sampled situations, the minimum re-evaluation interval is 30 seconds*. For pure situations like Unix Log Agent, the logs are rechecked every second. I am not sure how to answer their need... at a millisecond level. most measured items are running at 0% or 100%... I suspect they have not though through all the issues. * I know how to tweak a situation to change that lower - not with Situation Editor... but 1 second is the minimum. At that level the Agent might be consuming 50-80% of the system CPU - which does not sound practical. Regards, John Alvord - Ph: 1-720-396-2788 Cell: none Customer Support - Tivoli Software - jalvord-r/[email protected] Advisory Engineer - Tivoli Monitoring - ITM infrastructure Follow us on Twitter! @Tivolisupport and Facebook Personalize your support needs with the IBM Support Portal Use Service Request to get assistance! For emails regarding a PMR, copy [email protected] For secure browser uploads: https://www.ecurep.ibm.com/app/upload For Customer Support guidance: IBM Software Support Handbook From: Gregory Mendes <[email protected]> To: <[email protected]>, Date: 02/15/2013 07:58 AM Subject: [TME10] ITM Agents Logging Event Dectection in Milliseconds Sent by: [email protected] Hello All, I have a customer that has a requirement for millisecond logging of ITM agent events when they occur. I know that the Linux OS Agent and the Disk I/O situation can monitor in milliseconds. However, the real requirement is when an ITM agent detects a situation of any type, can it log that detection in a log file in milliseconds. I only see HH:MM:SS from local and global timestamps. Regards, Gregory R. Mendes 770-317-8593 _______________________________________________ TME10 mailing list [email protected] Unsubscribe:[email protected] _______________________________________________ TME10 mailing list [email protected] Unsubscribe:[email protected]_______________________________________________ TME10 mailing list [email protected] Unsubscribe:[email protected] _______________________________________________ TME10 mailing list [email protected] Unsubscribe:[email protected] _______________________________________________ TME10 mailing list [email protected] Unsubscribe:[email protected]