Re: Hub_TEMS FTO Timing

John Alvord <jalvord-r/[email protected]>
Newsgroups gmane.comp.sysutils.tivoli.general,gmane.comp.sysutils.tivoli.tme10
Message-ID <OF49F2F094.F712F9CE-ON88257BB2.0062FFCB-88257BB2.0063F409@us.ibm.com>
On FTO switchover.  I did find a minor improvement once

FTO Switch Time Speed Up
http://www.ibm.com/support/docview.wss?uid=swg21612077 

Part of the story is that TEMS heartbeat is 3 minutes default, but there 
is a 3 minute hard coded grace period. There is a second attempt to 
connect which can be controlled - see technote involved. Detection of a 
communications timeout is another factor - also suppression of new 
incoming work. There is a reason why the itmcmd server stop says it may 
take up to 10 minutes!!

Then there is the problem of the remote TEMS detecting a loss of hub. That 
is another series of delays. Some customers make it worse by listing 
multiple protocols to get to each hub TEMS

ip.pipe:server1
ip.spipe:server1
ip.pipe:server2
ip.spipe:server2

And if you lose ip.pipe - what do you think the chances are of having 
ip.spipe available and working on same TEMS?

We do not give any estimated time to switch over... you can see why.  My 
experience with large environments is 20-25 minutes is typical.

I suppose you could register the need with an RFE:

Tivoli Request For Enhancement (RFE)
http://www.ibm.com/support/docview.wss?uid=swg21449404  [announcement]
http://www.ibm.com/developerworks/rfe/tivoli/ 

There are other High Availability options besides FTO - HACMP and others. 
Maybe those would be speedier.

Regards, 
______________________________________________


John Alvord
Advisory Engineer
IBM Tivoli Monitoring 6 Platform
Customer Support 
Office: 1-720-396-2788 
Mobile: none 
jalvord-r/[email protected]

Cloud & Smarter Infrastructure
IBM Support Portal
Open a New Service Request
Update your PMR via Email
Escalate your PMR
My Blog: Wonderful World of Situations
Secure upload to ECUREP







From:   Gregory Mendes <[email protected]>
To:     "[email protected]" <[email protected]>, 
Date:   07/23/2013 12:11 PM
Subject:        [TME10] Hub_TEMS FTO Timing
Sent by:        [email protected]



Hello All,
 
Thanks in advance for your answers. 
 
I have a customer that has a 64 second requirement for FTO.  I look in the 
"Hot Standby" hub's ms log for "this hub is now the acting FTO primary". 
However, this action is taking longer than 64 seconds and sometimes 68 - 
70 seconds.
 
My question is when does the "Hot Standby" hub actually take over?  Is it 
immediately after loosing its heartbeat or when you actually see, "this 
hub is now the acting as primary"?
 
Regards,

Gregory R. Mendes
Tivoli Architect/Tools Specialist
Mendes, Inc.
Tivoli Monitoring 6.2.3 Certified
770-317-8593
_______________________________________________
TME10 mailing list
[email protected]
Unsubscribe:[email protected]

_______________________________________________
TME10 mailing list
[email protected]
Unsubscribe:[email protected]
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.