Re: ipV4 and ipV6

Miroslav Lichvar <[email protected]>
Newsgroups gmane.comp.time.chrony.user
Message-ID <Y4R1lKsr2MmJJrL6@localhost>
On Sat, Nov 26, 2022 at 06:29:55AM +0000, chengyechun wrote:
> Hi all
> When the chrony works in both IPv4 and IPv6 modes, for example, one client is configured with two servers, one server is iPv4 and the other is ipv6, and the NTS function is configured. I found that they were able to communicate, but the time source state was displayed as x, which was a bit odd since they didn't have a big time difference:
> [cid:image001.png-4ZskIHRzBpc/[email protected]]

The output shows that the sources are off by ~1.1 seconds from each
other, but the estimate of accuracy is only in hundreds of
microseconds. Their intervals don't overlap, so they are marked as
falsetickers.

It looks like two servers configured with the local reference mode.
That cannot work.

-- 
Miroslav Lichvar


-- 
To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "unsubscribe" in the subject.
For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "help" in the subject.
Trouble?  Email [email protected]