Re: chrony switch source issue

Miroslav Lichvar <[email protected]>
Newsgroups gmane.comp.time.chrony.user
Message-ID <Y7LRGqE33Y+mDrLL@localhost>
On Mon, Jan 02, 2023 at 12:22:56PM +0000, Bernstein, Amit wrote:
> As both source timestamp (NTP and PHC) are very close to each other
> And according to chrony faq: "It will let the clock run free for as long as its estimated error (in terms of root distance) based on previous measurements is smaller than the estimated error of the second source, and there is still an interval which contains some measurements from both sources."
> Chrony should have replaced the source from PHC to NTP after no more than several msec, I have waited about an hour and still saw chrony getting stucked on PHC source.

Please post output from chronyc sources, sourcestats, ntpdata,
selectdata.

-- 
Miroslav Lichvar


-- 
To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "unsubscribe" in the subject.
For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "help" in the subject.
Trouble?  Email [email protected]
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.