Re: Not using external server if stratum drops below acceptable number
Miroslav Lichvar <[email protected]>
| Newsgroups | gmane.comp.time.chrony.user |
|---|---|
| Message-ID | <ZCGQVzIGNp5v+Wb5@localhost> |
On Mon, Mar 27, 2023 at 01:30:05PM +0100, Simon Burke wrote: > My question is whether there is an option to stop using a particular source > if its stratum drops below an expected value. I suspect that the answer is > that it's not needed, but I just wanted to get some clarity for my > own understanding. In what cases do you think it might be needed? There is no option to do it directly. If you wanted to avoid selecting a high-stratum source when a low-stratum source is available, the stratumweight option could be set to a large value. -- Miroslav Lichvar -- To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "unsubscribe" in the subject. For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "help" in the subject. Trouble? Email [email protected]