Re: All network sources unusable

Bryan Christianson <[email protected]>
Newsgroups gmane.comp.time.chrony.user
Message-ID <[email protected]>
Hi Torsten

From the chrony.conf(5) manpage: 
noselect Never select this source. This is useful for monitoring or with sources which are not very accurate, but are locked with a PPS refclock.

Your 'noselect' hosts are not viable sources as they will never be selected. They will however show up in the 'chronyc sourcestats' list with their measured offsets.

If you look at the gpsd link again, you will see they are displaying 'chronyc sourcestats', not 'sources' as you have posted.

Also, I suggest you set the SHM 0 refclock to noselect - it will still be used by the pps refclock to give a timestamp to the pps readings but will not participate in setting the clock.

I hope that helps.

Regards, Bryan


-- 
Bryan Christianson
[email protected]




-- 
To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "unsubscribe" in the subject.
For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "help" in the subject.
Trouble?  Email [email protected]
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.