Re: All network sources unusable
Bryan Christianson <[email protected]>
| Newsgroups | gmane.comp.time.chrony.user |
|---|---|
| Message-ID | <[email protected]> |
Hi Torsten From the chrony.conf(5) manpage: noselect Never select this source. This is useful for monitoring or with sources which are not very accurate, but are locked with a PPS refclock. Your 'noselect' hosts are not viable sources as they will never be selected. They will however show up in the 'chronyc sourcestats' list with their measured offsets. If you look at the gpsd link again, you will see they are displaying 'chronyc sourcestats', not 'sources' as you have posted. Also, I suggest you set the SHM 0 refclock to noselect - it will still be used by the pps refclock to give a timestamp to the pps readings but will not participate in setting the clock. I hope that helps. Regards, Bryan -- Bryan Christianson [email protected] -- To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "unsubscribe" in the subject. For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "help" in the subject. Trouble? Email [email protected]