Re: refclock local with OCXO

Miroslav Lichvar <[email protected]>
Newsgroups gmane.comp.time.chrony.user
Message-ID <ZJ0xISouPNa0xaLF@localhost>
On Wed, Jun 28, 2023 at 07:31:29PM +0200, Stephanie Wilde-Hobbs wrote:
> Before buying hardware I want to make sure: will chrony
> will measure and correct for the frequency error and long-term drift in the
> OCXO using connected NTP servers?

It will measure the frequency offset relative to NTP sources or other
refclocks, but it will not correct it or do anything interesting with
it. It cares only about changes in the frequency to stabilize the
system clock as if you replaced the XO on the motherboard.

> If so, how will I monitor this frequency
> error to make sure the process is happening properly?

The frequency offset will be visible in the sourcestats report. The
phase offset will be moving between 0 and 1 second.

-- 
Miroslav Lichvar


-- 
To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "unsubscribe" in the subject.
For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "help" in the subject.
Trouble?  Email [email protected]