Re: refclock local with OCXO
Miroslav Lichvar <[email protected]>
| Newsgroups | gmane.comp.time.chrony.user |
|---|---|
| Message-ID | <ZJ1kAbz7G+A4Z6aa@localhost> |
On Thu, Jun 29, 2023 at 10:45:20AM +0200, Stephanie Wilde-Hobbs wrote: > Thank you very much, this seems to be what I want! Is the time period over > which the OCXO is assumed stable controlled by minsamples/maxsamples? That would the other sources' minpoll/maxpoll, minsamples/maxsamples and filter configuration. For the OCXO refclock you need to consider stability of the system clock and the noise in the measurements. It should have the shortest interval among all sources. -- Miroslav Lichvar -- To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "unsubscribe" in the subject. For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "help" in the subject. Trouble? Email [email protected]