On Tue, Aug 08, 2023 at 18:54:15 -0400, Josef 'Jeff' Sipek wrote: > On Tue, Aug 08, 2023 at 14:33:10 +0200, Miroslav Lichvar wrote: ... > > If the stabilization > > works well, the skew of other sources should become smaller and they > > should use more samples (NP). > > Noted. I restarted chrony this morning with the PPS configured but no > signal going in, then after ~4 hours (which I assume is enough for the > system to stabilize), I turned on the PPS signal. I'm going to give it a > few more hours and then look at the logs to see how the frequency skew of > the sources changed throughout the day - and especially after I enabled the > PPS signal. Just plotted the contents of statistics.log and I *think* things are better with PPS but not in a major way. NP is higher for 2 of the 3 NTP sources, and the Skew (called EstRateErr on my plots) seems more consistent between the sources but not amazingly better. However the trend was still downward, so maybe I terminated the experiment too early. This could all be, of course, because of USB being a terrible idea for PPS :) In case anyone wants to see, here are the plots I made. It's one plot for every column in statistics.log in order. (Beware, some plots use log scales and some use linear scales.) https://www.josefsipek.net/chrony-pps-experiment.pdf Thanks, Jeff. -- To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "unsubscribe" in the subject. For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "help" in the subject. Trouble? Email [email protected]