Re: Using cellular network clock as refclock in chrony
Miroslav Lichvar <[email protected]> Wed, 31 Jul 2024 10:52:08 +0200
| Newsgroups | gmane.comp.time.chrony.user |
|---|---|
| Message-ID | <Zqn7OGLuV_l4Gd-N@localhost> |
On Wed, Jul 31, 2024 at 08:42:52AM +0000, Amol Lad wrote: > refclock SOCK /var/run/chrony.cellular.sock precision 1 prefer poll 3 refid MODM > > (I tried reducing the poll to 1 but this does not seem to make any difference) Try adding "filter 1" to reduce the number of samples required per poll. Unlike with SHM, chronyd doesn't know how many SOCK samples there will be per poll, so it doesn't adjust the filter length automatically. -- Miroslav Lichvar -- To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "unsubscribe" in the subject. For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org with "help" in the subject. Trouble? Email [email protected]