Re: Using cellular network clock as refclock in chrony

Miroslav Lichvar <[email protected]> Wed, 31 Jul 2024 10:52:08 +0200
Newsgroups gmane.comp.time.chrony.user
Message-ID <Zqn7OGLuV_l4Gd-N@localhost>
On Wed, Jul 31, 2024 at 08:42:52AM +0000, Amol Lad wrote:
> refclock SOCK /var/run/chrony.cellular.sock precision 1 prefer poll 3 refid MODM
> 
> (I tried reducing the poll to 1 but this does not seem to make any difference)

Try adding "filter 1" to reduce the number of samples required per
poll. Unlike with SHM, chronyd doesn't know how many SOCK samples
there will be per poll, so it doesn't adjust the filter length
automatically.

-- 
Miroslav Lichvar


-- 
To unsubscribe email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "unsubscribe" in the subject.
For help email chrony-users-request-kWFZVVI9zxvPqho9SqqRMmD2FQJk+8+b@public.gmane.org 
with "help" in the subject.