This probably isn't a problem with not running ldconfig. Usually, not running this will cause missing lib errors and won't even load. Looking at the original problem, this could also be a mismatch between two different versions of Microwindows, where the structures have changed. I don't know that they have, but is another possible problem. Hope this helps, Jason Kingan Century Software On Thursday 06 February 2003 10:11 pm, you wrote: > This is the viewml binary that I've downloaded from the site. I copied the > libraries to /usr/lib. I forgot, though, to run the $ldconfig command. Do > you think this error has something to do with it ? But I'm not familiar > with ldconfig and I'm afraid that it might damage the system. Do you also > know where can I get a binary for arm of ldconfig ? Or its source ? > Thanks. > > Mildred > > > From: "Greg Haerr" <[email protected]> > Subject: Re: error running viewml binary > Date: Wed, 5 Feb 2003 22:13:39 -0700 > To: "ViewML development list" <[email protected]> > > > Usually this means that the threading package isn't working properly. > Be sure to recompile everything from scratch. > > Regards, > > Greg > ----- Original Message ----- > From: Mildred Frisco > To: ViewML development list > Sent: Wednesday, February 05, 2003 7:42 PM > Subject: error running viewml binary > > > > > Hi ! I've tried to run the viewml on the strongarm platform with > embedded linux. The platform already has nano-X running. I've copied the > shared libraries to /usr/lib and created the file > /home/jasonk/projects/arm/microwin/src/bin/nano-X, since the program was > looking for it when I first tried to run it. then i typed the following > commands > > $ nano-X & > $ viewml > > viewml produced the following errors: > > Client 153: wrong packet type 0 (expected 3) > Client 153: wrong packet type 240 (expected 3) > Client 153: wrong packet type 1 (expected 3) > Client 153: wrong packet type -2048 (expected 3) > . > . > . > Client 153: wrong packet type 2016 (expected 3) > Client 153: wrong packet type 31 (expected 3) > . > . > . > > > Please reply if you know this. > > Thank you very much > > > mildred ############################################################# This message is sent to you because you are subscribed to the mailing list <[email protected]>. To unsubscribe, E-mail to: <[email protected]> To switch to the DIGEST mode, E-mail to <[email protected]> To switch to the INDEX mode, E-mail to <[email protected]> Send administrative queries to <[email protected]>