Re: VECTOR: 6101 problems

"Steve P." <[email protected]> Tue, 26 Apr 2005 12:36:49 -0400
Newsgroups gmane.games.arcade.vector
Message-ID <005e01c54a7e$2509a150$9da34544@yourlk4rlmsu41>
----- Original Message ----- 
From: "joemagiera" <[email protected]>
To: <[email protected]>
Sent: Tuesday, April 26, 2005 11:55 AM
Subject: VECTOR: 6101 problems


  But when I checked the original fuses
> that were in there, I see they were 6.25A fuses.  I got the monitior with
> those fuses installed.  So I don't know if they just didn't have some 5A 
> on
> hand and sub-ed the closest thing they had (which worked for several 
> years),
> or they intentially upped the fuses because it was blowing the 5A.  The
> documentation, both in the manual and printed on the boardset call for 5A.
>

The upgraded cap kits replaces the 5As with 6.25 slo blo's, IIRC.


-Steve P.

All messages are scanned with Norton Anti-Virus