>4) examples
>
>I don't really have time (or enough info) to fill in the
>examples in section 4, but I know somebody will eventually
>ask about this before RFC publication.  I would really
>appreciate some help updating the examples.  (I need to
>add an example for entPhysicalClass==cpu(12) as well.)
>Any volunteers? (4.1 and 4.2 can be done independently)
>I would like to get this over with now ;-)



andy,

we came up with some acme-compatible URIs for the examples below;
see additions. also included the MfgDate. included examples for both
instantiated and non-instantiated cases.

kaj

--------------------------------------------------------------------




_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/

Kaj Tesink
Telcordia Technologies. Inc.
One Telcordia drive
Piscataway, NJ 08854
Email: [email protected]
Tel: (732) 699-6068
Fax: (732) 336-2336

_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/

--=====================_253135269==_
Content-Type: text/plain; charset="us-ascii"
Content-Disposition: attachment; filename="example.txt"




4.1.  Router/Bridge

     A router containing two slots.  Each slot contains a 3 port
     router/bridge module. Each port is represented in the ifTable.
     There are two logical instances of OSPF running and two logical
     bridges:

  Physical entities -- entPhysicalTable:
    1 Field-replaceable physical chassis:
      entPhysicalDescr.1 ==             'Acme Chassis Model 100'
      entPhysicalVendorType.1 ==        acmeProducts.chassisTypes.1
      entPhysicalContainedIn.1 ==       0
      entPhysicalClass.1 ==             chassis(3)
      entPhysicalParentRelPos.1 ==      0
      entPhysicalName.1 ==              '100-A'
      entPhysicalHardwareRev.1 ==       'A(1.00.02)'
      entPhysicalSoftwareRev.1 ==       ''
      entPhysicalFirmwareRev.1 ==       ''
      entPhysicalSerialNum.1 ==         'C100076544'
      entPhysicalMfgName.1 ==           'Acme'
      entPhysicalModelName.1 ==         '100'
      entPhysicalAlias.1 ==             'cl-SJ17-3-006:rack1:rtr-U3'
      entPhysicalAssetID.1 ==           '0007372293'
      entPhysicalIsFRU.1 ==             true(1)
      entPhysicalMfgDate.1              2002-5-26,13:30:30.0,-4:0
      entPhysicalUris.1                 URN:CLEI:CNME120ARA

    2 slots within the chassis:
      entPhysicalDescr.2 ==             'Acme Chassis Slot Type AA'
      entPhysicalVendorType.2  ==       acmeProducts.slotTypes.1
      entPhysicalContainedIn.2 ==       1
      entPhysicalClass.2 ==             container(5)
      entPhysicalParentRelPos.2 ==      1
      entPhysicalName.2 ==              'S1'
      entPhysicalHardwareRev.2 ==       'B(1.00.01)'
      entPhysicalSoftwareRev.2 ==       ''
      entPhysicalFirmwareRev.2 ==       ''
      entPhysicalSerialNum.2 ==         ''
      entPhysicalMfgName.2 ==           'Acme'
      entPhysicalModelName.2 ==         'AA'
      entPhysicalAlias.2 ==             ''
      entPhysicalAssetID.2 ==           ''
      entPhysicalIsFRU.2 ==             false(2)
      entPhysicalMfgDate.2              2002-7-26,12:22:12.0,-4:0
      entPhysicalUris.2                 URN:CLEI:CNME123ARA

      entPhysicalDescr.3 ==             'Acme Chassis Slot Type AA'
      entPhysicalVendorType.3 =         acmeProducts.slotTypes.1
      entPhysicalContainedIn.3 ==       1
      entPhysicalClass.3 ==             container(5)
      entPhysicalParentRelPos.3 ==      2
      entPhysicalName.3 ==              'S2'
      entPhysicalHardwareRev.3 ==       '1.00.07'
      entPhysicalSoftwareRev.3 ==       ''
      entPhysicalFirmwareRev.3 ==       ''
      entPhysicalSerialNum.3 ==         ''
      entPhysicalMfgName.3 ==           'Acme'
      entPhysicalModelName.3 ==         'AA'
      entPhysicalAlias.3 ==             ''
      entPhysicalAssetID.3 ==           ''
      entPhysicalIsFRU.3 ==             false(2)
      entPhysicalMfgDate.3              2002-7-26,12:12:12.0,-4:0
      entPhysicalUris.3                 URN:CLEI:CNME123ARA


    2 Field-replaceable modules:
    Slot 1 contains a module with 3 ports:
      entPhysicalDescr.4 ==             'Acme Router-100'
      entPhysicalVendorType.4  ==       acmeProducts.moduleTypes.14
      entPhysicalContainedIn.4 ==       2
      entPhysicalClass.4 ==             module(9)
      entPhysicalParentRelPos.4 ==      1
      entPhysicalName.4 ==              'M1'
      entPhysicalHardwareRev.4 ==       '1.00.07'
      entPhysicalSoftwareRev.4 ==       '1.4.1'
      entPhysicalFirmwareRev.4 ==       'A(1.1)'
      entPhysicalSerialNum.4 ==         'C100087363'
      entPhysicalMfgName.4 ==           'Acme'
      entPhysicalModelName.4 ==         'R100-FE'
      entPhysicalAlias.4 ==             'rtr-U3:m1:SJ17-3-eng'
      entPhysicalAssetID.4 ==           '0007372462'
      entPhysicalIsFRU.4 ==             true(1)
      entPhysicalMfgDate.4              2003-7-18,13:30:30.0,-4:0
      entPhysicalUris.4                 URN:CLEI:CNRU123CAA


      entPhysicalDescr.5 ==             'Acme Ethernet-100 Port'
      entPhysicalVendorType.5  ==       acmeProducts.portTypes.2
      entPhysicalContainedIn.5 ==       4
      entPhysicalClass.5 ==             port(10)
      entPhysicalParentRelPos.5 ==      1
      entPhysicalName.5 ==              'P1'
      entPhysicalHardwareRev.5 ==       'G(1.02)'
      entPhysicalSoftwareRev.5 ==       ''
      entPhysicalFirmwareRev.5 ==       '1.1'
      entPhysicalSerialNum.5 ==         ''
      entPhysicalMfgName.5 ==           'Acme'
      entPhysicalModelName.5 ==         'FE-100'
      entPhysicalAlias.5 ==             ''
      entPhysicalAssetID.5 ==           ''
      entPhysicalIsFRU.5 ==             false(2)
      entPhysicalMfgDate.5              2003-7-18,14:20:22.0,-4:0
      entPhysicalUris.5                 URN:CLEI:CNMES23ARA


      entPhysicalDescr.6 ==             'Acme Ethernet-100 Port'
      entPhysicalVendorType.6  ==       acmeProducts.portTypes.2
      entPhysicalContainedIn.6 ==       4
      entPhysicalClass.6 ==             port(10)
      entPhysicalParentRelPos.6 ==      2
      entPhysicalName.6 ==              'P2'
      entPhysicalHardwareRev.6 ==       'G(1.02)'
      entPhysicalSoftwareRev.6 ==       ''
      entPhysicalFirmwareRev.6 ==       '1.1'
      entPhysicalSerialNum.6 ==         ''
      entPhysicalMfgName.6 ==           'Acme'
      entPhysicalModelName.6 ==         'FE-100'
      entPhysicalAlias.6 ==             ''
      entPhysicalAssetID.6 ==           ''
      entPhysicalIsFRU.6 ==             false(2)
      entPhysicalMfgDate.6              2003-7-19,10:15:15.0,-4:0
      entPhysicalUris.6                 URN:CLEI:CNMES23ARA


      entPhysicalDescr.7 ==             'Acme Router-100 FDDI-Port'
      entPhysicalVendorType.7  ==       acmeProducts.portTypes.3
      entPhysicalContainedIn.7 ==       4
      entPhysicalClass.7 ==             port(10)
      entPhysicalParentRelPos.7 ==      3
      entPhysicalName.7 ==              'P3'
      entPhysicalHardwareRev.7 ==       'B(1.03)'
      entPhysicalSoftwareRev.7 ==       '2.5.1'
      entPhysicalFirmwareRev.7 ==       '2.5F'
      entPhysicalSerialNum.7 ==         ''
      entPhysicalMfgName.7 ==           'Acme'
      entPhysicalModelName.7 ==         'FDDI-100'
      entPhysicalAlias.7 ==             ''
      entPhysicalAssetID.7 ==           ''
      entPhysicalIsFRU.7 ==             false(2)


   Slot 2 contains another 3-port module:
      entPhysicalDescr.8 ==             'Acme Router-100 Comm Module'
      entPhysicalVendorType.8  ==       acmeProducts.moduleTypes.15
      entPhysicalContainedIn.8 ==       3
      entPhysicalClass.8 ==             module(9)
      entPhysicalParentRelPos.8 ==      1
      entPhysicalName.8 ==              'M2'
      entPhysicalHardwareRev.8 ==       '2.01.00'
      entPhysicalSoftwareRev.8 ==       '3.0.7'
      entPhysicalFirmwareRev.8 ==       'A(1.2)'
      entPhysicalSerialNum.8 ==         'C100098732'
      entPhysicalMfgName.8 ==           'Acme'
      entPhysicalModelName.8 ==         'C100'
      entPhysicalAlias.8 ==             'rtr-U3:m2:SJ17-2-eng'
      entPhysicalAssetID.8 ==           '0007373982'
      entPhysicalIsFRU.8 ==             true(1)
      entPhysicalMfgDate.8              2002-5-26,13:30:15.0,-4:0
      entPhysicalUris.8                 URN:CLEI:CNRT321MAA


      entPhysicalDescr.9 ==             'Acme Fddi-100 Port'
      entPhysicalVendorType.9 ==        acmeProducts.portTypes.5
      entPhysicalContainedIn.9 ==       8
      entPhysicalClass.9 ==             port(10)
      entPhysicalParentRelPos.9 ==      1
      entPhysicalName.9 ==              'FDDI Primary'
      entPhysicalHardwareRev.9 ==       'CC(1.07)'
      entPhysicalSoftwareRev.9 ==       '2.0.34'
      entPhysicalFirmwareRev.9 ==       '1.1'
      entPhysicalSerialNum.9 ==         ''
      entPhysicalMfgName.9 ==           'Acme'
      entPhysicalModelName.9 ==         'FDDI-100'
      entPhysicalAlias.9 ==             ''
      entPhysicalAssetID.9 ==           ''
      entPhysicalIsFRU.9 ==             false(2)


      entPhysicalDescr.10 ==            'Acme Ethernet-100 Port'
      entPhysicalVendorType.10 ==       acmeProducts.portTypes.2
      entPhysicalContainedIn.10 ==      8
      entPhysicalClass.10 ==            port(10)
      entPhysicalParentRelPos.10 ==     2
      entPhysicalName.10 ==             'Ethernet A'
      entPhysicalHardwareRev.10 ==      'G(1.04)'
      entPhysicalSoftwareRev.10 ==      ''
      entPhysicalFirmwareRev.10 ==      '1.3'
      entPhysicalSerialNum.10 ==        ''
      entPhysicalMfgName.10 ==          'Acme'
      entPhysicalModelName.10 ==        'FE-100'
      entPhysicalAlias.10 ==            ''
      entPhysicalAssetID.10 ==          ''
      entPhysicalIsFRU.10 ==            false(2)
      entPhysicalMfgDate.10             2002-7-26,13:30:15.0,-4:0
      entPhysicalUris.10                URN:CLEI:CNMES23ARA


      entPhysicalDescr.11 ==            'Acme Ethernet-100 Port'
      entPhysicalVendorType.11 ==       acmeProducts.portTypes.2
      entPhysicalContainedIn.11 ==      8
      entPhysicalClass.11 ==            port(10)
      entPhysicalParentRelPos.11 ==     3
      entPhysicalName.11 ==             'Ethernet B'
      entPhysicalHardwareRev.11 ==      'G(1.04)'
      entPhysicalSoftwareRev.11 ==      ''
      entPhysicalFirmwareRev.11 ==      '1.3'
      entPhysicalSerialNum.11 ==        ''
      entPhysicalMfgName.11 ==          'Acme'
      entPhysicalModelName.11 ==        'FE-100'
      entPhysicalAlias.11 ==            ''
      entPhysicalAssetID.11 ==          ''
      entPhysicalIsFRU.11 ==            false(2)
      entPhysicalMfgDate.11             2002-8-16,15:35:15.0,-4:0
      entPhysicalUris.11                URN:CLEI:CNMES23ARA









--=====================_253135269==_
Content-Type: text/plain; charset="us-ascii"
MIME-Version: 1.0
Content-Transfer-Encoding: 7bit
Content-Disposition: inline

_______________________________________________
Entmib mailing list
[email protected]
https://www1.ietf.org/mailman/listinfo/entmib

--=====================_253135269==_--