RE: Clarifications in EPON Device MIB
Rajagopalan Subramanian <[email protected]>
| Newsgroups | gmane.ietf.hubmib |
|---|---|
| Message-ID | <[email protected]_nt.centillium.com> |
Hello Mr.Khermosh, One more query in addition to the ones I sent few days back. 3. In the dot3MpcpEntry table : there are two fields dot3MpcpReceiverSettlingTime and dot3MpcpCdrLockTime. We donot have any reference to these in the 802.3ah drafts. If I am not wrong, these two are replaced by the 'SyncTime' in the draft 1.414 itself. Should we reflect this in the MIB too? Or am I missing something?! Thanks Raj. -----Original Message----- From: Rajagopalan Subramanian Sent: Monday, February 16, 2004 5:49 PM To: 'Lior Khermosh'; '[email protected]' Cc: Hariprasad V. Nair Subject: RE: Clarifications in EPON Device MIB Hello Mr. Khermosh, Thanks for your reply. I am forwarding the earlier questions posted by me and your reply for that, to the mailing list. Few more questions on your reply : 1. Currently, as far as I know, the standard 802.3ah does not suggest a de-asserting mechanism. While standard specify a way to report the Critical link event, link fault and Dying Gasp events in the form of Flags field in the OAMPDU, it does not talk about resetting them. Similar is the case for all the Errored Events though an assertion and de-assertion is possible in this case without deviating from the standard, I think. However all the Global Events, Temperature and Voltage specific events and the Vendor SpecificAlarm Events, are not defined in the standard. Can they be optional then? 2. One thing I missed to point out in my previous mail : Attribute eponDeviceObjectOrganizationSpecificEventState seems to be identical to the eponDeviceObjectVendorSpecificEventState attribute. Or are they different? Please clarify. Thanks Raj Subramanian. -----Original Message----- From: Lior Khermosh [mailto:[email protected]] Sent: Sunday, February 15, 2004 12:34 PM To: Rajagopalan Subramanian Subject: RE: Clarifications in EPON Device MIB Dear Mr. Subramanian, Thank you very much for your comments. They are very helpful. I would like to ask the permission to send the comments and replies to the hubmib reflector for the interest of all people. eponDeviceObjectOnuLoopback - As defined now it is redundant and should be removed. From eponDeviceObjectDyingGaspAlarmState : When the dyingGaspAlarm state is removed the dying gasp alarm is reset. I added it to the text. eponDeviceObjectTemperatureEventIndicationState, eponDeviceObjectPowerVoltageEventIndicationState , eponDeviceObjectGlobalEvent0State...................... eponDeviceObjectGlobalEvent7State The alarms are not defined at the 802.3ah draft. I will remove this reference. However I still think that as alarms and event for device in access system they are needed so I suggest to keep them. I will add a description. eponDeviceObjectVendorSpecificAlarmState, eponDeviceObjectVendorSpecificEventState The alarms are not defined at the 802.3ah draft. I will remove this reference. However I still think that as alarms and event for device in access system they are needed. Iwill add a description. The difference in my opinion is: Alarm: When the value of the alarm input is above the threshold defined for the alarm the alarm is asserted. When the condition is below that threshold the alarm is de-asserted. Event: When the indication of the event input occurs the event is asserted. When the input is removed that event is de-asserted. Event is more referring to a system condition while alarm indicates a bad thing happening in the system. eponDeviceObjectPowerDown I think it is. An ONU might have a battery back up and when the device is starting to get down it indicates Power down. In my opinion it is a very important indication for the carrier. Best regards, Lior Khermosh -----Original Message----- From: Rajagopalan Subramanian [mailto:[email protected]] Sent: Wednesday, February 11, 2004 6:51 AM To: '[email protected]' Cc: Rajagopalan Subramanian Subject: Clarifications in EPON Device MIB Hello Mr.Khermosh, I have few questions in the Device MIB that you had proposed as part of the draft-ietf-hubmib-efm-epon-mib-00. I would appreciate if you can help me get it clarified. eponDeviceObjectOnuLoopback - In what way is this attribute different from the one defined in the EFM MIB, dot3OamLoopbackCommand. In an implementation should both of these be supported? From eponDeviceObjectDyingGaspAlarmState (Entry 8) to eponDeviceObjectOrganizationSpecificEventState(Entry 27) - The SYNTAX in the MIB attribute says it's a TruthValue and the description says that 'this bit should be asserted when we receive the corresponding event'. My question is : The bit will be set when we receive an event but when will we reset it ? It cannot be always '1' whenever the user reads this attribute, right? eponDeviceObjectTemperatureEventIndicationState, eponDeviceObjectPowerVoltageEventIndicationState , eponDeviceObjectGlobalEvent0State...................... eponDeviceObjectGlobalEvent7State The description says ' this event defines the state of the *respective* event of the OAM Alarm Indications as specified in the [802.3ah] clause 57. But I could not locate these attributes in the Draft2.0 version of the standard. Can you give me pointers as to where I should be looking into? eponDeviceObjectVendorSpecificAlarmState, eponDeviceObjectVendorSpecificEventState The description for these two attributes are Identical. I could not a VendorAlarm and a VendorEvent, separately in the clause 57. Can you give some info please? eponDeviceObjectPowerDown Is setting the PowerDown a valid scenario for the EPON? Thanks for your time. Regards, Raj Subramanian Centillium India, Bangalore, INDIA +91 80 25523575