RE: Questions regarding Power Ethernet MIB

"Romascanu, Dan (Dan)" <[email protected]>
Newsgroups gmane.ietf.hubmib
Message-ID <AAB4B3D3CF0F454F98272CBE187FDE2FF546A7@IS0004AVEXU1.global.avaya.com>
Steve,

Thank you for your comments. 

You are correct about issues #1 and #3. We will fix accordingly in the next version of the I-D.

Concerning #2, the SMIv2 recommendation is to make indices non-accessible rather than read-only.

Regards,

Dan


> -----Original Message-----
> From: [email protected] [mailto:[email protected]]
> Sent: Thursday, March 14, 2002 11:51 PM
> To: '[email protected]'; Romascanu, Dan (Dan)
> Subject: Questions regarding Power Ethernet MIB
> 
> 
> Dear Avi and Dan, 
> 
> I'm Steve Ko. I'm working on the Power Ethernet MIB right 
> now. I've got
> three questions regarding Power Ethernet MIB. 
> 
> These questions are: 
> 1) In pethPsePortGroupIndex, the index starts at 1. Why does the index
>    start at 0 in pethMainPseGroupIndex and 
> pethTrapsControlGroupIndex? 
>    Is there any special meaning? Normally, the index starts 
> at 1 in other
>    MIBs.
> 2) Why is pethMainPseGroupIndex not-accessible? Normally, the 
> index is 
>    read-only, isn't it? 
> 3) In pethMainPseBackUpActivatedTrap, pethMainPowerUsageOnTrap, 
>    pethMainPowerUsageOffTrap, shall the pethPsePortGroupIndex 
> be replaced
>    with pethMainPseGroupIndex?
>     
> 
> The MIB file I have is 
> <draft-ietf-hubmib-power-ethernet-mib-01.txt>. You
> reply is highly appreciated. Thanks!
> 
> Regards, 
> 
> Steve Ko 
> Delta Networks, Inc.  
> 
>   
> 
>         
>
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.