RE: Questions regarding Power Ethernet MIB
"Romascanu, Dan (Dan)" <[email protected]>
| Newsgroups | gmane.ietf.hubmib |
|---|---|
| Message-ID | <AAB4B3D3CF0F454F98272CBE187FDE2FF546A7@IS0004AVEXU1.global.avaya.com> |
Steve, Thank you for your comments. You are correct about issues #1 and #3. We will fix accordingly in the next version of the I-D. Concerning #2, the SMIv2 recommendation is to make indices non-accessible rather than read-only. Regards, Dan > -----Original Message----- > From: [email protected] [mailto:[email protected]] > Sent: Thursday, March 14, 2002 11:51 PM > To: '[email protected]'; Romascanu, Dan (Dan) > Subject: Questions regarding Power Ethernet MIB > > > Dear Avi and Dan, > > I'm Steve Ko. I'm working on the Power Ethernet MIB right > now. I've got > three questions regarding Power Ethernet MIB. > > These questions are: > 1) In pethPsePortGroupIndex, the index starts at 1. Why does the index > start at 0 in pethMainPseGroupIndex and > pethTrapsControlGroupIndex? > Is there any special meaning? Normally, the index starts > at 1 in other > MIBs. > 2) Why is pethMainPseGroupIndex not-accessible? Normally, the > index is > read-only, isn't it? > 3) In pethMainPseBackUpActivatedTrap, pethMainPowerUsageOnTrap, > pethMainPowerUsageOffTrap, shall the pethPsePortGroupIndex > be replaced > with pethMainPseGroupIndex? > > > The MIB file I have is > <draft-ietf-hubmib-power-ethernet-mib-01.txt>. You > reply is highly appreciated. Thanks! > > Regards, > > Steve Ko > Delta Networks, Inc. > > > > >