RE: FW: EPON MIB comments
"Romascanu, Dan \(Dan\)" <[email protected]>
| Newsgroups | gmane.ietf.hubmib |
|---|---|
| Message-ID | <AAB4B3D3CF0F454F98272CBE187FDE2F038A9FE6@is0004avexu1.global.avaya.com> |
> > > > eponDeviceTemperatureEventIndicationState > > > > eponDeviceTemperatureEventIndicationEnabled > > > > eponDevicePowerVoltageEventIndicationState > > > > eponDevicePowerVoltageEventIndicationEnabled > > Where are these objects reflected in the management clause of > 802.3ah? I'm not a fan of adding new things at this stage of > the game. Temp and voltage measurements and events aren't > generally within the purview of 802.3. > I agree with Glen and Matt, although reflecting the objects from the management clause of 802.3ah is not a requirement. I made the comment at IETF-59 that RFC 3433 (Entity Sensor MIB) would be a better solution for temperature and voltage indication. Regards, Dan (speaking as contributor) >