Hi Everyone--
I was reviewing this draft and found the following inconsistencies:
::= { pethPsePortEntry 8 }
pethPsePortPowerMaintenanceStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
underCurrent(2),
mPSAbsent(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value ok(1) indicates the Power Maintenance
Signature is present and the overcurrent condition has not been
detected.
The value overCurrent (2) indicates an overcurrent condition
has been detected.
The value mPSAbsent(3) indicates that the Power Maintenance
Signature is absent."
REFERENCE "[IEEE Draft P802.3af/D3.3, October, 2002, 30.9.1.1.8
aPSEPowerMaintenanceStatus]"
The 802.3af/D4.0, November 14, 2002 has values of ok, MPSAbsent, and
overCurrent. Shouldn't this match?
::= { pethPsePortEntry 11 }
pethPsePortOverCurrentCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of times that the aPSEPowerCurrentStatus
attribute changes from any value to the value
overCurrent(2)."
REFERENCE "[IEEE Draft P802.3af/D3.3, October, 2002, object
30.9.1.1.10
aPSEOverCurrentCounter]"
I believe the description should read pethPsePortPowerMaintenanceStatus and
not aPSEPowerCurrentStatus and the Reference should change to
aPSEPowerMaintenanceStatus to match 802.3af.
Thanks,
Scott