ncs sig mib draft 5 updates - summary

Beacham Gordon-CGB005 <[email protected]>
Newsgroups gmane.ietf.ipcdn
Message-ID <D5A7E45D575DD61180130002A5DB377C06529116@ca25exm01>
It's been brought to my attention the pktcNcsEndPntConfig[Min/Max]HookFlash ranges are not in sync. The syntax for pktcNcsEndPntConfigMaxHookFlash has been changed to 20..1000 to be in sync with the pktcNcsEndPntConfigMinHookFlash range. Thanks for catching this David & Satish.
 
Also, the following MIB description changes have been made to sync up with the latest Cablelabs Signaling MIB ECR.
 
pktcSigDefMediaStreamDscp  OBJECT-TYPE 

    SYNTAX      Dscp  -- RFC 3289: DIFFSERV-DSCP-TC 

    MAX-ACCESS  read-write 

    STATUS      current 

    DESCRIPTION 

        " This object contains the default value used in the IP

          header for setting the Differentiated Services Code Point

          (DSCP) value for media stream packets. The MTA MUST NOT

          update this object with the value supplied by the CMS in

          the NCS messages (if present). When the value of this

          object is updated by SNMP, the MTA MUST use the new value

          as a default starting only from the new connection.

          Existing connections are not affected by the value's

          update."

 

pktcNcsEndPntConfigCallAgentId     OBJECT-TYPE 

    SYNTAX      SnmpAdminString(SIZE (3..255)) 

    MAX-ACCESS  read-create 

    STATUS      current 

    DESCRIPTION 

        " This object contains a string indicating the call agent

          name (e.g.: [email protected]). The call agent name, after

          the character '@', MUST be a fully qualified domain name

          and MUST have a corresponding pktcMtaDevCmsFqdn entry in

          the pktcMtaDevCmsTable. The object pktcMtaDevCmsFqdn is

          defined in the PacketCable MIBMTA Specification. For each

          particular endpoint, the MTA MUST use the current value

          of this object to communicate with the corresponding

          CMS. The MTA MUST update this object with the value of the

          'Notified Entity' parameter of the NCS messages when

          provided. Because of the high importance of this object to

          the ability of the MTA to maintain reliable NCS

          communication with the CMS, it is highly recommended not

          to change this object's value through management

          station during normal operations." 

 

pktcNcsEndPntConfigCallAgentUdpPort    OBJECT-TYPE 

    SYNTAX      InetPortNumber (1025..65535) 

    MAX-ACCESS  read-create  

    STATUS      current 

    DESCRIPTION 

        " This object contains the current value of the User

          Datagram Protocol (UDP) receive port on which the

          call agent will receive NCS signaling from the endpoint.

          For each particular endpoint, the MTA MUST use the current

          value of this object to communicate with the corresponding

          CMS. The MTA MUST update this object with the value of the

          'Notified Entity' parameter of the NCS messages when

          provided. Because of the high importance of this object to

          the ability of the MTA to maintain reliable NCS

          communication with the CMS, it is highly recommended not

          to change this object's value through management

          station during normal operations." 

 

pktcNcsEndPntConfigBusyToneTO     OBJECT-TYPE 

    SYNTAX       Unsigned32 

    UNITS        "seconds" 

    MAX-ACCESS   read-create 

    STATUS       current 

    DESCRIPTION 

        " This object contains the default timeout value for busy

          tone. The MTA MUST NOT update this object with the

          value provided in the NCS message (if present). If

          the value of the object is modified by the SNMP Management

          Station, the MTA MUST use the new value as a default only

          for a new signal requested by the NCS message." 

 

pktcNcsEndPntConfigDialToneTO     OBJECT-TYPE 

    SYNTAX       Unsigned32 

    UNITS        "seconds" 

    MAX-ACCESS   read-create 

    STATUS       current 

    DESCRIPTION 

        " This object contains the default timeout value for dial

          tone. The MTA MUST NOT update this object with the

          value provided in the NCS message (if present). If

          the value of the object is modified by the SNMP Management

          Station, the MTA MUST use the new value as a default only

          for a new signal requested by the NCS message." 

 

pktcNcsEndPntConfigMessageWaitingTO     OBJECT-TYPE 

    SYNTAX       Unsigned32 

    UNITS        "seconds" 

    MAX-ACCESS   read-create 

    STATUS       current 

    DESCRIPTION 

        " This object contains the default timeout value for message

          waiting indicator. The MTA MUST NOT update this object

          with the value provided in the NCS message (if

          present). If the value of the object is modified by the

          SNMP Management Station, the MTA MUST use the new value as

          a default only for a new signal requested by the NCS

          message." 

 

pktcNcsEndPntConfigOffHookWarnToneTO     OBJECT-TYPE 

    SYNTAX       Unsigned32 

    UNITS        "seconds" 

    MAX-ACCESS   read-create 

    STATUS       current 

    DESCRIPTION 

        " This object contains the default timeout value for the off

          hook Warning tone. The MTA MUST NOT update this object

          with the value provided in the NCS message (if

          present). If the value of the object is modified by the

          SNMP Management Station, the MTA MUST use the new value as

          a default only for a new signal requested by the NCS

          message." 

 

pktcNcsEndPntConfigRingingTO     OBJECT-TYPE 

    SYNTAX       Unsigned32 

    UNITS        "seconds" 

    MAX-ACCESS   read-create 

    STATUS       current 

    DESCRIPTION 

        " This object contains the default timeout value for

          ringing. The MTA MUST NOT update this object with the

          value provided in the NCS message (if present). If

          the value of the object is modified by the SNMP Management

          Station, the MTA MUST use the new value as a default only

          for a new signal requested by the NCS message." 

 

pktcNcsEndPntConfigRingBackTO     OBJECT-TYPE 

    SYNTAX       Unsigned32 

    UNITS        "seconds" 

    MAX-ACCESS   read-create 

    STATUS       current 

    DESCRIPTION 

        " This object contains the default timeout value for ring

          back. The MTA MUST NOT update this object with the

          value provided in the NCS message (if present). If

          the value of the object is modified by the SNMP Management

          Station, the MTA MUST use the new value as a default only

          for a new signal requested by the NCS message." 

 

pktcNcsEndPntConfigReorderToneTO     OBJECT-TYPE 

    SYNTAX       Unsigned32 

    UNITS        "seconds" 

    MAX-ACCESS   read-create 

    STATUS       current 

    DESCRIPTION 

        " This object contains the default timeout value for reorder

          tone. The MTA MUST NOT update this object with the

          value provided in the NCS message (if present). If

          the value of the object is modified by the SNMP Management

          Station, the MTA MUST use the new value as a default only

          for a new signal requested by the NCS message." 

 

pktcNcsEndPntConfigStutterDialToneTO     OBJECT-TYPE 

    SYNTAX       Unsigned32 

    UNITS        "seconds" 

    MAX-ACCESS   read-create 

    STATUS       current 

    DESCRIPTION 

        " This object contains the default timeout value for stutter

          dial tone. The MTA MUST NOT update this object with the

          value provided in the NCS message (if present). If

          the value of the object is modified by the SNMP Management

          Station, the MTA MUST use the new value as a default only

          for a new signal requested by the NCS message." 

 

pktcNcsEndPntConfigCallWaitingMaxRep     OBJECT-TYPE 

    SYNTAX      Unsigned32 (0..10) 

    MAX-ACCESS  read-create 

    STATUS      current 

    DESCRIPTION 

        " This object contains the default value of the maximum

          number of repetitions of the call waiting tone that the

          MTA will play from a single CMS request. The MTA MUST NOT

          update this object with the information provided in the

          NCS message (if present). If the value of the object is

          modified by the SNMP Management Station, the MTA MUST use

          the new value as a default only for a new signal

          requested by the NCS message." 

 

 

Gordon