It's been brought to my attention the pktcNcsEndPntConfig[Min/Max]HookFlash ranges are not in sync. The syntax for pktcNcsEndPntConfigMaxHookFlash has been changed to 20..1000 to be in sync with the pktcNcsEndPntConfigMinHookFlash range. Thanks for catching this David & Satish.
Also, the following MIB description changes have been made to sync up with the latest Cablelabs Signaling MIB ECR.
pktcSigDefMediaStreamDscp OBJECT-TYPE
SYNTAX Dscp -- RFC 3289: DIFFSERV-DSCP-TC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object contains the default value used in the IP
header for setting the Differentiated Services Code Point
(DSCP) value for media stream packets. The MTA MUST NOT
update this object with the value supplied by the CMS in
the NCS messages (if present). When the value of this
object is updated by SNMP, the MTA MUST use the new value
as a default starting only from the new connection.
Existing connections are not affected by the value's
update."
pktcNcsEndPntConfigCallAgentId OBJECT-TYPE
SYNTAX SnmpAdminString(SIZE (3..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains a string indicating the call agent
name (e.g.: [email protected]). The call agent name, after
the character '@', MUST be a fully qualified domain name
and MUST have a corresponding pktcMtaDevCmsFqdn entry in
the pktcMtaDevCmsTable. The object pktcMtaDevCmsFqdn is
defined in the PacketCable MIBMTA Specification. For each
particular endpoint, the MTA MUST use the current value
of this object to communicate with the corresponding
CMS. The MTA MUST update this object with the value of the
'Notified Entity' parameter of the NCS messages when
provided. Because of the high importance of this object to
the ability of the MTA to maintain reliable NCS
communication with the CMS, it is highly recommended not
to change this object's value through management
station during normal operations."
pktcNcsEndPntConfigCallAgentUdpPort OBJECT-TYPE
SYNTAX InetPortNumber (1025..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the current value of the User
Datagram Protocol (UDP) receive port on which the
call agent will receive NCS signaling from the endpoint.
For each particular endpoint, the MTA MUST use the current
value of this object to communicate with the corresponding
CMS. The MTA MUST update this object with the value of the
'Notified Entity' parameter of the NCS messages when
provided. Because of the high importance of this object to
the ability of the MTA to maintain reliable NCS
communication with the CMS, it is highly recommended not
to change this object's value through management
station during normal operations."
pktcNcsEndPntConfigBusyToneTO OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the default timeout value for busy
tone. The MTA MUST NOT update this object with the
value provided in the NCS message (if present). If
the value of the object is modified by the SNMP Management
Station, the MTA MUST use the new value as a default only
for a new signal requested by the NCS message."
pktcNcsEndPntConfigDialToneTO OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the default timeout value for dial
tone. The MTA MUST NOT update this object with the
value provided in the NCS message (if present). If
the value of the object is modified by the SNMP Management
Station, the MTA MUST use the new value as a default only
for a new signal requested by the NCS message."
pktcNcsEndPntConfigMessageWaitingTO OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the default timeout value for message
waiting indicator. The MTA MUST NOT update this object
with the value provided in the NCS message (if
present). If the value of the object is modified by the
SNMP Management Station, the MTA MUST use the new value as
a default only for a new signal requested by the NCS
message."
pktcNcsEndPntConfigOffHookWarnToneTO OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the default timeout value for the off
hook Warning tone. The MTA MUST NOT update this object
with the value provided in the NCS message (if
present). If the value of the object is modified by the
SNMP Management Station, the MTA MUST use the new value as
a default only for a new signal requested by the NCS
message."
pktcNcsEndPntConfigRingingTO OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the default timeout value for
ringing. The MTA MUST NOT update this object with the
value provided in the NCS message (if present). If
the value of the object is modified by the SNMP Management
Station, the MTA MUST use the new value as a default only
for a new signal requested by the NCS message."
pktcNcsEndPntConfigRingBackTO OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the default timeout value for ring
back. The MTA MUST NOT update this object with the
value provided in the NCS message (if present). If
the value of the object is modified by the SNMP Management
Station, the MTA MUST use the new value as a default only
for a new signal requested by the NCS message."
pktcNcsEndPntConfigReorderToneTO OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the default timeout value for reorder
tone. The MTA MUST NOT update this object with the
value provided in the NCS message (if present). If
the value of the object is modified by the SNMP Management
Station, the MTA MUST use the new value as a default only
for a new signal requested by the NCS message."
pktcNcsEndPntConfigStutterDialToneTO OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the default timeout value for stutter
dial tone. The MTA MUST NOT update this object with the
value provided in the NCS message (if present). If
the value of the object is modified by the SNMP Management
Station, the MTA MUST use the new value as a default only
for a new signal requested by the NCS message."
pktcNcsEndPntConfigCallWaitingMaxRep OBJECT-TYPE
SYNTAX Unsigned32 (0..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This object contains the default value of the maximum
number of repetitions of the call waiting tone that the
MTA will play from a single CMS request. The MTA MUST NOT
update this object with the information provided in the
NCS message (if present). If the value of the object is
modified by the SNMP Management Station, the MTA MUST use
the new value as a default only for a new signal
requested by the NCS message."
Gordon