IETF NCS Sig MIB draft 6 -> Issue for pktcSigDevToneWholeToneRepe atCount/pktcSigDevToneSteady when duration is shorter than TO
Beacham Gordon-CGB005 <[email protected]>
| Newsgroups | gmane.ietf.ipcdn |
|---|---|
| Message-ID | <D5A7E45D575DD61180130002A5DB377C06529343@ca25exm01> |
Satish,
Thanks for raising this issue. The intent of the pktcSigDevToneWholeToneRepeatCount and pktcSigDevToneSteady was to support telco industry standards. If a tone definition using repeat count objects results in a tone sequence that is shorter than the TO time, the repeat count takes significance. I checked the NCS spec on this issue and I don't see a clear indication of expected behaviour when a tone duration is shorter than an associated TO.
Do you have text you would like to propose as a solution for the description of these objects?
Comments?
Gordon
>The MIbs specify the case where longer duration is set. However they do not specifically say what to do in the case >where setting the pktcSigDevToneWholeToneRepeatCount results in a tone duration which is shorter than the tone >duration which is specified through the timeout (TO)???
>What is the expected duration behavior in this case?? Does the MTA has to observe the specified number of repeat counts?? or does it stick to the value in timeout(TO) MIB? Please throw some light on expected behavior.
pktcSigDevToneWholeToneRepeatCount OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the repeat count, which signifies how many times
to repeat the entire on-off sequence. Setting this object
may result in a tone duration longer than the overall
signal duration specified by the time out (TO) object for a
particular signal. In this case, the tone duration defined
by the TO object for a particular signal always represents
the overall signal duration for a tone."
::={ pktcSigDevToneEntry 18 }
pktcSigDevToneSteady OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the steady tone. Device must play out the on-off
sequence for pktcSigDevToneWholeRepeatCount times and
then apply the last tone forever. Setting this object
may result in a tone duration longer than the overall
signal duration specified by the time out (TO) object for a
particular signal. In this case, the tone duration defined
by the TO object for a particular signal always represents
the overall signal duration for a tone."
::={ pktcSigDevToneEntry 19 }
_______________________________________________
IPCDN mailing list
[email protected]
https://www1.ietf.org/mailman/listinfo/ipcdn