Additional comments on draft-ietf-ipcdn-device-mibv2-06.txt

"Randy Presuhn" <[email protected]>
Newsgroups gmane.ietf.ipcdn
Message-ID <012301c3b445$9b42df60$7f1afea9@oemcomputer>
Hi -

Bert Wijnen ran SMICng on the MIB module in
draft-ietf-ipcdn-device-mibv2-06.txt and
found some items that I overlooked:

>   E: f(ipcdndevice.mi2), (1342,1) Row "docsDevFilterIpEntry" must have
>      same status as parent table "docsDevFilterIpTable"

This must be fixed.

>   E: f(ipcdndevice.mi2), (2389,12) Item "diffServMIBDataPathGroup" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2390,12) Item "diffServMIBClfrGroup" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2391,12) Item "diffServMIBClfrElementGroup" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2392,12) Item "diffServMIBMultiFieldClfrGroup" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2393,12) Item "diffServMIBActionGroup" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2394,12) Item "diffServMIBDscpMarkActGroup" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2395,12) Item "diffServMIBCounterGroup" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2396,12) Item "diffServMIBAlgDropGroup" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2399,8) Item "diffServDataPathStatus" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2406,8) Item "diffServClfrStatus" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2413,8) Item "diffServClfrElementStatus" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2420,8) Item "diffServMultiFieldClfrAddrType" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2426,8) Item "diffServMultiFieldClfrSrcAddr" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2433,8) Item "diffServMultiFieldClfrDstAddr" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2439,8) Item "diffServAlgDropStatus" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2446,8) Item "diffServDataPathStorage" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2452,8) Item "diffServClfrStorage" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2458,8) Item "diffServClfrElementStorage" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2464,8) Item "diffServMultiFieldClfrStorage" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2470,8) Item "diffServActionStorage" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2476,8) Item "diffServCountActStorage" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2482,8) Item "diffServAlgDropStorage" should be IMPORTed
>   E: f(ipcdndevice.mi2), (2488,8) Item "diffServAlgDropType" should be IMPORTed

The MIB review guidelines recommend that these be imported.  This is not a
hard requirement, but the consensus of the MIB reviewer mailing list was that
having IMPORTS for these makes it easier for someone reading a module to
see the dependencies in one place.

Since this is an update to an existing specification, I'm also going to run it through
smidiff, and will post comments regarding those results in a separate message.

Randy
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.