RE: Re: IETF IPCDN Signaling MIB - Draft 3 - Last Call fo r Comments (pktcSigPulseSignalDbLevel range)
Beacham Gordon-CGB005 <[email protected]>
| Newsgroups | gmane.ietf.ipcdn |
|---|---|
| Message-ID | <D5A7E45D575DD61180130002A5DB377C06528C22@ca25exm01> |
Yes, agree that a more reasonable range should be considered for the pktcSigPulseSignalDbLevel object. In looking at the meter pulse range for this object, the max value specified in 300 001 is for Sweden (-30 dBm). Motorola recommends setting the range of this object to (-350..0) to accommodate Sweden and to allow some margin for other international countries. This range is specified at the analog POTs interface (i.e., the a-b terminals). > Independent of this, it might worth noting that the current range of the "pktcSigPulseSignalDbLevel" MIB Object (-250..152) is very large considering only one of the modes (meterPulse) uses it and the country specifications do not require it to be so high. We would recommend reducing this to a more reasonable range of (-250..0). Gordon Beacham Digital Core Gateways, BCS Motorola, Inc. 858-404-2335 [email protected]