RE: Editorial Changes - NCS MIB
"Woundy, Richard" <[email protected]>
| Newsgroups | gmane.ietf.ipcdn |
|---|---|
| Message-ID | <E1DDBE5DF628DC40A36761E03AF5CCFFD7C08F@divexcg03.cable.comcast.com> |
I agree with Azlina about not moving pktcSigNotification.
In fact,
<http://www.ietf.org/internet-drafts/draft-ietf-ops-mib-review-guidelines-02
.txt> goes further in section 4.7:
4.7. Notification Definitions
RFC 2578 Section 8 specifies the rules for notification definitions.
In particular:
- Inaccessible objects MUST NOT appear in the OBJECTS clause.
- For each object type mentioned in the OBJECTS clause, the
DESCRIPTION clause MUST specify which object instance is to be
present in the transmitted notification and MUST specify the
information/meaning conveyed.
- The OBJECT IDENTIFIER (OID) value assigned to each notification
type MUST have a next-to-last sub-identifier of zero, so that it is
possible to convert an SMIv2 notification definition into an SMIv1
trap definition and back again without information loss (see
[RFC2576] Section 2.1.2) and possible for a multilingual proxy
chain to translate an SNMPv2 trap into an SNMPv1 trap and back
again without information loss (see [RFC2576] Section 3). In
addition, the OID assigned to a notification definition MUST NOT
also be assigned to another definition that results in OID
registration. RFC 2578 Section 3.6 lists the constructs that
create OID registrations.
...
The key requirement above is that the "OBJECT IDENTIFIER (OID) value
assigned to each notification type MUST have a next-to-last sub-identifier
of zero".
-- Rich
-----Original Message-----
From: [email protected] [mailto:[email protected]]On Behalf Of
Azlina Ahmad
Sent: Tuesday, March 30, 2004 3:15 PM
To: Beacham Gordon-CGB005
Cc: [email protected]
Subject: Re: [ipcdn] Editorial Changes - NCS MIB
Beacham Gordon-CGB005 wrote:
> The following editorial changes have been suggested for the NCS MIB:
>
> 1. Remove the pktcSigEndPntConfigObjects defintion. All endpoint
configuration objects are located under
> pktcNcsEndPntConfigObjects, while pktcSigEndPntConfigObjects has no
objects.
>
> 2. Reorder the R0, R6 and R7 objects so that R0, R1, R2, R3, R4, R5, R6,
R7, Rg and Rs form a sequential series.
>
> 3. Change pktcSigNotification OBJECT IDENTIFIER ::= { pktcSigMib 0 } to:
> pktcSigNotification OBJECT IDENTIFIER ::= { pktcSigMib 2 }
Recommend keeping the notification as it is per Appendix D
of the draft-ietf-ops-mib-review-guidelines-02.txt.
Thanks,
Azlina
>
> Gordon Beacham
> Digital Core Gateways, BCS
> Motorola, Inc.
> 858-404-2335
> [email protected]
>
>