re: pktcSigPulseSignalDbLevel range

Beacham Gordon-CGB005 <[email protected]>
Newsgroups gmane.ietf.ipcdn
Message-ID <D5A7E45D575DD61180130002A5DB377C0652909F@ca25exm01>
In reviewing the ipcdn archives I note we did not achieve resolution on the revised syntax range for the pktcSigPulseSignalDbLevel object. See: http://www1.ietf.org/mail-archive/web/ipcdn/current/msg01077.html <http://www1.ietf.org/mail-archive/web/ipcdn/current/msg01077.html> 
 
>In looking at the meter pulse range for this object, the max value specified in 300 001 is for Sweden (-30 dBm).
>Motorola recommends setting the range of this object to (-350..0) to accommodate Sweden and to allow some margin for other international countries.
 
Comments?
 
Gordon Beacham
Digital Core Gateways, BCS
Motorola, Inc.
858-404-2335
[email protected]