re: pktcSigPulseSignalDbLevel range
Beacham Gordon-CGB005 <[email protected]>
| Newsgroups | gmane.ietf.ipcdn |
|---|---|
| Message-ID | <D5A7E45D575DD61180130002A5DB377C0652909F@ca25exm01> |
In reviewing the ipcdn archives I note we did not achieve resolution on the revised syntax range for the pktcSigPulseSignalDbLevel object. See: http://www1.ietf.org/mail-archive/web/ipcdn/current/msg01077.html <http://www1.ietf.org/mail-archive/web/ipcdn/current/msg01077.html> >In looking at the meter pulse range for this object, the max value specified in 300 001 is for Sweden (-30 dBm). >Motorola recommends setting the range of this object to (-350..0) to accommodate Sweden and to allow some margin for other international countries. Comments? Gordon Beacham Digital Core Gateways, BCS Motorola, Inc. 858-404-2335 [email protected] _______________________________________________ IPCDN mailing list [email protected] https://www1.ietf.org/mailman/listinfo/ipcdn