Bharat Joshi <[email protected]> Wed, 12 Oct 2011 21:20:11 +0530
| Newsgroups | gmane.ietf.magma |
|---|---|
| Message-ID | <31D55C4D55BEED48A4459EB64567589A1186EB24EB@BLRKECMBX02.ad.infosys.com> |
Kunal,
What I am suggesting is that though RFC does not explicitly suggest it, it might be better to do this for broadcast interfaces.
But yes, RFC does not suggest anything on this so a host can process a query message with a source address from any other subnet as well.
Regards,
Bharat
________________________________________
From: Kunal Shah [[email protected]]
Sent: Wednesday, October 12, 2011 9:17 PM
To: Bharat Joshi; [email protected]
Subject: RE: Question about IGMP host implementation
Hi Bharat,
The security consideration addresses the processing of a report from a different subnet on the router. My question pertains to the processing of a Query from a different subnet on the host.
Kunal
-----Original Message-----
From: Bharat Joshi [mailto:[email protected]]
Sent: Wednesday, October 12, 2011 4:20 AM
To: Kunal Shah; [email protected]
Subject: RE: Question about IGMP host implementation
Hi Kunal,
I think to keep the security tight, it is better to not respond to queries received from a source address which does not fall on a subnet on that interface. Please note that this should be done only broadcast interfaces. It may not work on point-to-point links.
If you look at the security consideration in RFC 2236, it is mentioned that for reports, the above check should be done.
Regards,
Bharat
________________________________________
From: [email protected] [[email protected]] On Behalf Of Kunal Shah [[email protected]]
Sent: Wednesday, October 12, 2011 6:08 AM
To: [email protected]
Subject: [magma] Question about IGMP host implementation
Hi all,
Can an IGMPv2 host respond to a general query originated from a subnet other then its own?? RFC 2236 states:
""query received" occurs when the host receives either a valid
General Membership Query message, or a valid Group-Specific
Membership Query message. To be valid, the Query message must be
at least 8 octets long, and have a correct IGMP checksum. The
group address in the IGMP header must either be zero (a General
Query) or a valid multicast group address (a Group-Specific Query)"
There is no requirement for the source address to be on the same subnet as the host.
Thanks,
Kunal
**************** CAUTION - Disclaimer ***************** This e-mail contains PRIVILEGED AND CONFIDENTIAL INFORMATION intended solely for the use of the addressee(s). If you are not the intended recipient, please notify the sender by e-mail and delete the original message. Further, you are not to copy, disclose, or distribute this e-mail or its contents to any other person and any such actions are unlawful. This e-mail may contain viruses. Infosys has taken every reasonable precaution to minimize this risk, but is not liable for any damage you may sustain as a result of any virus in this e-mail. You should carry out your own virus checks before opening the e-mail or attachment. Infosys reserves the right to monitor and review the content of all messages sent to or from this e-mail address.
Messages sent to or from this e-mail address may be stored on the Infosys e-mail system.
***INFOSYS******** End of Disclaimer ********INFOSYS***