[manet] Re: Gunter Van de Velde's No Objection on draft-ie tf-manet-dlep-credit-flow-control-17: (with COMMENT)

"Gunter van de Velde \(Nokia\)" <[email protected]>
Newsgroups gmane.ietf.manet
Message-ID <AS1PR07MB8589AFD4B24B1C2F712527EAE0AD2@AS1PR07MB8589.eurprd07.prod.outlook.com>
Thanks Donald.

Be well,
G/

-----Original Message-----
From: Donald Eastlake <[email protected]> 
Sent: Monday, March 24, 2025 4:16 PM
To: Gunter van de Velde (Nokia) <[email protected]>
Cc: The IESG <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]
Subject: Re: Gunter Van de Velde's No Objection on draft-ietf-manet-dlep-credit-flow-control-17: (with COMMENT)


CAUTION: This is an external email. Please be very careful when clicking links or opening attachments. See the URL nok.it/ext for additional information.



Hi Gunter,

On Thu, Feb 6, 2025 at 7:28 AM Gunter Van de Velde via Datatracker <[email protected]> wrote:
>
> Gunter Van de Velde has entered the following ballot position for
> draft-ietf-manet-dlep-credit-flow-control-17: No Objection
>
> ...
>
> ----------------------------------------------------------------------
> COMMENT:
> ----------------------------------------------------------------------
>
> # Gunter Van de Velde, RTG AD, comments for
> draft-ietf-manet-dlep-credit-flow-control-17
>
> # The line numbers used are rendered from IETF idnits tool:
> https://author-tools.ietf.org/api/idnits?url=https://www.ietf.org/arch
> ive/id/draft-ietf-manet-dlep-credit-flow-control-17.txt
>
> # Many thanks to Dhruv Dhody  for the RTGDIR review, and the follow up.
>
> # Detailed Review
> # ===============
>
> 400        Length:
> 401           16
> 402
> 403           Per [RFC8175] Length is the number of octets in the Data Item.  It
> 404           MUST be equal to sixteen (16).
>
> GV> This field seems slightly underspecified. Maybe point out that the 
> GV> Length
> is set in multiples of bytes, not bits. GV> What must happen if the 
> length is not set to value '16'? ignore? send a trap? reset the 
> process? Please advice

The description says "number of octets" which seems to already say that it is in bytes, not bits.

If the length is a value other than 16, then the Data Item is corrupt and the message including that Data Item is ignored. Wording to this effect has been added in version -18.

> 496        Length:
> 497           2
> 498
> 499           Per [RFC8175] Length is the number of octets in the Data Item.  It
> 500           MUST be equal to two (2).
>
> GV> similar observation as above.

Similar response. And similar parallel changes have been made elsewhere in the draft.

Thanks,
Donald
===============================
 Donald E. Eastlake 3rd   +1-508-333-2270 (cell)
 2386 Panoramic Circle, Apopka, FL 32703 USA  [email protected]




> Kind Regards,
> Gunter Van de Velde
> Routing Area Director
_______________________________________________
manet mailing list -- [email protected]
To unsubscribe send an email to [email protected]
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.