RE: Megaco digitmap timer
"Kevin Boyle" <[email protected]>
| Newsgroups | gmane.ietf.megaco |
|---|---|
| Message-ID | <34B3EAA5B3066A42914D28C5ECF5FEA41310DA39@zrtphxm2.corp.nortel.com> |
I do not believe that inference to be correct, and the use of brackets
in this way does not appear to be terribly constructive.
Note that these are square brackets and not braces. Braces are "{}".
Remember that square brackets specify a choice, and are not used to
denote a subset. In this particular instance the DigitMap is allowing
the MG to choose between a digit from 0-9 and the long interdigit timer.
I don't see where that would ever be a desired option in the normal
processing of digits.
Kevin
________________________________
From: Ramesh Babu Kuppili [mailto:[email protected]]
Sent: Friday, December 28, 2007 1:38 AM
To: [email protected]
Subject: [Megaco] Megaco digitmap timer
Hi,
I have a question about megaco digitmap timer.
What is the scope of a timer (L or S) within a range in a megaco
digitmap. For example:
In the digitmap:
15xSxxx[Lx]xxxx
My inference from the rfc is (taking a dial sequence of 15105551212
Digit dialled Timer started
1 L
5 L
1 L
0 S
5 S
5 S
5 L (this is within the braces.
my assumption is that the timer specifier within braces is valid only
within braces)
1 S
2 S
1 S
2 S
Is my inference correct that timer specifier within a brace is valid
only within the brace.
- ramesh
_______________________________________________
Megaco mailing list
[email protected]
https://www1.ietf.org/mailman/listinfo/megaco