Re: Multiple Streams and mutiplex terminations

Christian Groves <[email protected]> Thu, 20 Oct 2011 20:12:15 +1100
Newsgroups gmane.ietf.megaco
Message-ID <[email protected]>
Hello Javi,

Did you see my email on the 18/10 which discusses this? Even with the 
clarification of the Terminations there's some questions.

Regards, Christian

On 20/10/2011 7:38 PM, Javi Muñoz wrote:
> Does MeGaCo support the next contexts?:
>
>
>   Tmux1=Mux(1x64K(TermA/StreamID=1,TermA/StreamID=2,TermB/StreamID=1)) 
> -- * -- TermC (HDLCPW1)
>                                     |
> TermA (ISDN D-Channel, UNI p)       |
>    StreamID=1 (SAPI 16, TEI r)------|
>    StreamID=2 (SAPI 16, TEI s)------|
>                                     |
> TermB (ISDN D-Channel, UNI q)       |
>    StreamID=1 (SAPI 16, TEI r)------|
>    StreamID=2 (SAPI 16, TEI s)------------|
>    StreamID=3 (SAPI 16, TEI t)------------|
>                                           |
>                     Tmux2=Mux(1x64K(TermB/StreamID=2,TermB/StreamID=3) 
> -- * -- TermD (HDLCPW2)
>
>
> where:
>
> (a) Every multiplex termination is multiplexing Streams from different 
> ISDN terminations, and only any Streams of each termination.
>
> (b) The result of the multiplexion must be a flow of "64 kbps".
>
> Javi Muñoz
> _______________________________________________
> Megaco mailing list
> [email protected]
> https://www.ietf.org/mailman/listinfo/megaco
>