Re: ASP Capabilities value 0x2 of interworking field
"Brian F. G. Bidulock" <[email protected]>
| Newsgroups | gmane.ietf.sigtran |
|---|---|
| Organization | http://www.openss7.org/ |
| Message-ID | <[email protected]> |
Ilie, Ilie Glib wrote: (Mon, 19 Dec 2005 12:39:07) > Brian, > > could you please answer the following questions > > 1) Can SG register via RKM? If not, why the value 0x2 that indicates > Signalling Gateway? You are confused. 0x2 indicates signalling gateway capability: i.e., the registering node has an SS7 network interfaces and behaves as an SG when interworking to that interface. > > 2) Is there any difference between capabilities 0x0 and 0x1 in SUA > > 0x0 indicates no interworking with SS7 Networks. > 0x1 indicates IP Signalling Endpoint (ASP), interworking with SS7 > networks. Yes, one supports interworking with SS7 networks and the other does not. > > I was more after a definition of the Relay capability in SUA > framework. Although SUA RFC mentions Relay and describes it, the > definition of Relay is missing. See SCCP specifications for a definition of a relay node. --brian -- Brian F. G. Bidulock [email protected] http://www.openss7.org/