RE: SUA - Routing Key Management Procedures
"Coene, Lode" <[email protected]>
| Newsgroups | gmane.ietf.sigtran |
|---|---|
| Message-ID | <67043E463DDBFD4A8087ED940BFF756B78475C@BRU0038A.ww018.siemens.net> |
Dear Warren, I did run a compare on the section you mentioned. Yes it is somewhat lighter than the M3UAbis document... What I can do is to include the text from the M3UAbis not found in SUA and SUA IG in the SUA IG and see if it makes sense... I would publish this next week then... Yours sincerely Lode Coene Siemens COM atealaan 34 2200 Herentals, Belgium E-mail: [email protected] Tel: +32-14-252081 Fax: +32-14-253212 > -----Original Message----- > From: [email protected] > [mailto:[email protected]] On Behalf Of Warren Anthony Briggs > Sent: dinsdag 14 februari 2006 1:55 > To: [email protected] > Subject: [Sigtran] SUA - Routing Key Management Procedures > > Dear All, > Section 4.4 of the M3UA draft-ietf-sigtran-rfc3332bis-06.txt document > provides a thorough description of the Routing Key > Management Procedures. > In particular the handling of events "Error - Routing Key Already > Registered" and "ERR Routing Key Change Refused". > The SUA Implementors Guide seems a little inconsistant with M3UA or > perhaps light (IMHO) in the descriptions for handling dynamic > registration. > > Will this area of the SUA IG to be brought into line with the M3UA > documentation? > > thanks, > Warren > > > > _______________________________________________ > Sigtran mailing list > [email protected] > https://www1.ietf.org/mailman/listinfo/sigtran >