Re: SIGTRAN:XUA Control message Rx

"Brian F. G. Bidulock" <[email protected]>
Newsgroups gmane.ietf.sigtran
Organization http://www.openss7.org/
Message-ID <[email protected]>
Saraswati,

Saraswati Bose wrote:                           (Sun, 16 Jul 2006 23:41:09)
> 
>    For  example,  if ASP receives an error message against ASP UP message
>    sent then should it retransmit the same UP message again?

Depends on the error and whether it is considered a permanent or temporary
situation.  For example, if the error is "Refused - Management Blocking,"
it would make sense for the ASP to reattempt ASP UP periodically.  If the
error is something like "Parameter Field Error," it is a permanent condition
and a reattempt is likely to acheive the same effect.  Nevertheless, it is
possible to reattempt periodically and inform management, and perhaps after
a number of reattempts give up.  This is all rather implementation dependent.

--brian

-- 