Re: [SCTP] Minimum DATA Length possible

ash kat <[email protected]>
Newsgroups gmane.ietf.sigtran
Message-ID <[email protected]>
Hi
   
  M2PA surely can take advantage of SCTP multihoming feature and the number of IP addresses assigned to an SCTP association is implementors choice.
   
  Regards,
  Ashwani kathuria
  FSS India.
  
Robby Pocornie <[email protected]> wrote:
    Hi All,
   
  I am designing a SIGTRAN network. Can you explain to me how the multi-homing IP-subaddresses possible can defined.
  1. I have 4 M3UA cards connection to  ASP (MSC-server)
  2. 4 M2PA cards connection to SGW (STP)
  3. Is SCTP multi-homing also applicable for M2PA connection between 2 SGW (STP).
  If multihoming is possible for M2PA, how many addresses i need for one subnet.
   
  Regards;
  Robby Pocornie
  [email protected]
 
   
  
 
  2006/7/19, Brian F. G. Bidulock <[email protected]>:   ash,

ash kat wrote:                                   (Wed, 19 Jul 2006 03:35:00)
>
>    What  is the minimum possible length of user DATA which can be sent by 
>    SCTP DATA chunk?

1-byte.

--brian


--
Brian F. G. Bidulock
[email protected]
http://www.openss7.org/ 

_______________________________________________
Sigtran mailing list
[email protected]
https://www1.ietf.org/mailman/listinfo/sigtran 




 				
---------------------------------
Do you Yahoo!?
 Next-gen email? Have it all with the  all-new Yahoo! Mail Beta.

_______________________________________________
Sigtran mailing list
[email protected]
https://www1.ietf.org/mailman/listinfo/sigtran
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.