M3UA: IPSP: RC configuration
"May, Howard" <[email protected]>
| Newsgroups | gmane.ietf.sigtran |
|---|---|
| Message-ID | <ABE7B4813B88E84AA64F7A0FD0CF7CB346DCBE@swsmsx412.ger.corp.intel.com> |
Hello, I am struggling to understand the intention for RC configuration between IPSPs using SE exchange. Consider a simple system: Three IPSPs each with a single AS - PC1, PC2 and PC3. Each AS has a signalling relationship with the other two ASs. The problem: At an IPSP there should be a 1-1-1 relationship between AS, RK and RC. So there is no way of configuring the system with a single AS at each IPSP. Is it expected that each Point Code will be modelled as a number of ASs, one for each signalling relationship? Best Regards Howard May Senior Engineer Intel Fordingbridge, Hampshire, UK +44 (0) 1425 651300 ext: 328 [email protected] www.intel.com/go/ss7 _______________________________________________ Sigtran mailing list [email protected] https://www1.ietf.org/mailman/listinfo/sigtran