M3UA: IPSP: RC configuration

"May, Howard" <[email protected]>
Newsgroups gmane.ietf.sigtran
Message-ID <ABE7B4813B88E84AA64F7A0FD0CF7CB346DCBE@swsmsx412.ger.corp.intel.com>
Hello,

I am struggling to understand the intention for RC configuration between
IPSPs using SE exchange.

Consider  a simple system:
Three IPSPs each with a single AS - PC1, PC2 and PC3.  Each AS has a
signalling relationship with the other two ASs.

The problem:
At an IPSP there should be a 1-1-1 relationship between AS, RK and RC.
So there is no way of configuring the system with a single AS at each
IPSP.

Is it expected that each Point Code will be modelled as a number of ASs,
one for each signalling relationship?

Best Regards

Howard May
Senior Engineer
Intel
Fordingbridge, Hampshire, UK
+44 (0) 1425 651300 ext: 328
[email protected]
www.intel.com/go/ss7

_______________________________________________
Sigtran mailing list
[email protected]
https://www1.ietf.org/mailman/listinfo/sigtran