debasri,

debasri Sarkar wrote:                                                              (Tue, 10 Jul 2007 18:26:06)
> 
>    Hi Brian,
> 
> 
> 
>    Thanks a lot for the explanation.
> 
> 
>    For  question  1,  it is justified that we can send data indication to
>    level 3 user
> 
>    and   DATA_ACK  to  PT,  as  there  is  no  way  to  send  a  negative
>    acknowledgement.
> 
> 
> 
>    For  question  2,  it  is absolutely right that the M2PA test draft is
>    inline with Test case Q.781/8.11
> 
>    of  MTP2  test  specification.  But, if OOS is  send after 2 wrong BSN
>    reception (not waiting
> 
>    for  the  third), will it violate the MTP2 specs Q.703/5.3.1 ? What is
>    your view in this regard?

See Figure 14/Q.703 (sheet 3 of 7) Basic reception control.  The SDLs
show link failure being signalled in response to the reception of the
second abnormal BSNR.

It is likely shown that way in Q.781/8.11 because to not show the
third FISU would mislead one into thinking that continuous FISUs
with bad BSNs are sent.  Same for m2pa-test.

--brian


-- 
Brian F. G. Bidulock