Re: single/double exchange mode doubt
"Brian F. G. Bidulock" <[email protected]>
| Newsgroups | gmane.ietf.sigtran |
|---|---|
| Organization | http://www.openss7.org/ |
| Message-ID | <[email protected]> |
Ankit, Ankit Kumar Sharma wrote: (Tue, 17 Jul 2007 11:31:59) > > Where have I written that ASP-Active is sent by IPSP-A for rc=y? > For rc=y, ASP-Active is sent from IPSP-1 towards IPSP-A(Please see > statement (3) above). > Following diagram gives a much clearer view of this scenario. > +----+ +----+ > |AS-1 | |AS-A | > |rc=x | |rc=x | > +----* *----+ > \\ // > \\ // > \\ // > *------+ +------+/ > |IPSP-1+--------------+IPSP-A| > /*------+ +------+ > // > // > +----* > |AS-2 | > |rc=y | > +-----+ > In SE mode an AS exists at both ends of the association or not at all. rc=x is valid in you diagram by rc=y is not. If an AS with rc=y does not exist at IPSP-A, then it will not be sending ASP-Active(rc=y) to IPSP-1. Put an AS-B(rc=y) at IPSP-A and your problems vanish. --brian -- Brian F. G. Bidulock [email protected] http://www.openss7.org/