David,

David Laight wrote:                                                 (Tue, 09 Oct 2007 11:12:49)
> We are implementing the M3UA protocol and I have a query
> about how the registration protocol is used in 'real life'.
> 
> The RFC seems to allow rather more flexibility that seems
> strictly necessary (I guess this has something to do with
> the differing views of those on the original comittee).
> 
> 1) The registration procedures are marked as optional.
>    Is it 'normal' to use these procedures ?

Depends what you mean by normal.  ETSI TS 102 142 forbids it.

> 
> 2) If the registration procedures are not used, what is
>    used to identify the connecting client ?
>    The only possible items are the IP address and the
>    ASP Identifier from the ASP up message.  Neither seems ideal.
>    (Clearly this is less of a problem if the server connects
>    to the client - since the client can be configured to send
>    all its outbound traffic to any server.)

It provides no more information to have the server connect to the
client.

> 
> 3) The Routing key parameter seems to allow more flexibility
>    than any application could possibly want.
>    I can see why it multiple dpc, si and opc might be needed.
>    But, since multiple routing contexts are also allowed, why
>    the values are grouped as triplets - allowing, for instance,
>    different si values for different remote pointcodes.
>    In the non-IPSP case the dpc surely has to be that of the SS7
>    MTP3 stack in the server system.

Perhaps mre flexibility that you know how to use.  Even moderate
side local switches have multiple point codes to circimvent CIC
limitations.  In the multiple SG as STP configuration, the registered
point code is never the "server's" point code.

>    
> 4) Reading the mailing list archive I notice that it is suggested to
>    not use the 'double-exchange' for IPSP.

More than suggested: SE is recommended (meaning that DE is
counter-recommended).

>    Is it worth (trying) to implement DE ?

No.

>    Is it reasonable to detect a SE IPSP connection from the 'reversed'
>    opc/dpc fields in the registation request ?

OPC and DPC are not reversed for SE: they are the same as ASP/SG.

--brian

> 
> 	David
> 
> Registered Address Lakeside, Bramley Road, Mount Farm, Milton Keynes, MK1 1PT, UK
> Registration No: 1397386 (Wales)  
> P Please consider the environment and don't print this e-mail unless you really need to
> 
> 
> _______________________________________________
> Sigtran mailing list
> [email protected]
> https://www1.ietf.org/mailman/listinfo/sigtran

-- 
Brian F. G. Bidulock
[email protected]
http://www.openss7.org/
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.