Re: Processor Outage and Resynchronizing Sequence Numbers
"Hecht Martin" <[email protected]>
| Newsgroups | gmane.ietf.sigtran |
|---|---|
| Message-ID | <849535E338E99741B7F7413F73253EDB0A0D53BC@us-nj-mail1.comverse.com> |
Brian,
Excuse me for using a brand name in my email, I meant no disrespect to
the product I named.
I am running test 3.4.1-1 from the M2PA Test 08 Specification. After
the exchange of READY messages of step (12) synchronization is not
happening at SP B and the Data Messages from SP B are sent with, what SP
A considers to be, an invalid FSN. SP A is discarding the data messages
and SP B takes the link Out-of-Service due to T7 excessive delay of ACK.
SP A READY BSN 1 FSN 1 --------------->
<--------------- SP B READY BSN 1 FSN 3
<--------------- SP B Data Msg. BSN 1
FSN 4
SP A Data Msg. BSN 1 FSN 2 ---------------->
<--------------- SP B Empty Data Msg.
BSN 2 FSN 4
<--------------- SP B Link Status OOS
My understanding is that the Data Message from SP B after the exchange
of READY messages should have an FSN of 2. SP A is discarding both the
Data Message and the Empty Data Message.
Best regards,
Martin
-----Original Message-----
From: Brian F. G. Bidulock [mailto:[email protected]]
Sent: Monday, February 23, 2009 5:02 PM
To: Hecht Martin
Cc: [email protected]
Subject: Re: [Sigtran] Processor Outage and Resynchronizing Sequence
Numbers
Martin,
Please don't use brand names on this list.
"if this is required by MTP2"
Resynchronization is required by ITU-T Q.703 1996,
ETSI EN 300 008-1, and ANSI T1.111.3/2000.
However, I am a little bit confused as to why you
think that the one end synchronizing and the other
end not will cause a problem. Could you provide
a message sequence chart for what you think the
problem will be?
--brian
Hecht Martin wrote: (Mon, 23 Feb 2009
11:41:15)
>
> To the mailing list,
>
> In the M2PA RFC it details how to resynchronize sequence numbers
after
> LPR/RPR as follows:
>
> M2PA (at both the LPO and RPO ends) uses the BSN value in the
> received Link Status Ready message to resynchronize its
sequence
> numbers, if this is required by MTP2.
>
>
> The problem is the "required by MTP2" issue. If one side
> resynchronizes its FSN to the BSN received in the READY message,
but
> the other side didn't implement this, then the FSN on the next MSU
> received would be wrong and the MSU will be discarded.
>
> For example, I am running M2PA conformance tests against the INET.
It
> doesn't resynchronize its FSN to the incoming BSN as described
above.
> So the next FSN sent by the Inet is not expected and is discarded.
>
> So, the question is, is the resynchronizing really optional? Or am
I
> misunderstanding the meaning of synchronize and the FSN is not set
to
> the BSN of the incoming READY message?
>
> Thanks,
>
> Martin
>
> Martin Hecht
> Engineering
>
> Signaling Core Group
> Comverse
> Office: +856 608-2712
> [1][email protected]
> [2]www.comverse.com
>
> References
>
> 1. mailto:[email protected]
> 2. http://www.comverse.com/
> _______________________________________________
> Sigtran mailing list
> [email protected]
> https://www.ietf.org/mailman/listinfo/sigtran
--
Brian F. G. Bidulock
[email protected]
http://www.openss7.org/